{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2018-14788 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2018-14788 yet. Limit exposure of the affected software until one is available.","what":"CVE-2018-14788 is a medium-severity memory corruption vulnerability in Fuji Electric Alpha5 Smart Loader, published on 1 Oct 2018. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2018-14788 and fix it if it is affected.\n\nWhat it is: CVE-2018-14788 is a medium-severity memory corruption vulnerability in Fuji Electric Alpha5 Smart Loader, published on 1 Oct 2018. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2018-14788 in the wild and no public exploit code.\n\nAffected product: Fuji Electric Alpha5 Smart Loader. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2018-14788/ (Markdown: https://insights.sbomify.com/CVE-2018-14788/index.md)","id":"CVE-2018-14788","markdown":"https://insights.sbomify.com/CVE-2018-14788/index.md","name":"CVE-2018-14788","record":{"aliases":["GHSA-px49-x446-6h5j"],"analysis":{"component_type":"ics_ot","fix_type":"upgrade","impacts":["data_read"],"network_reachable":"yes","non_default_config":false,"product_category":"Industrial PLC software","requires_auth":"none","summary":"A buffer overflow in Fuji Electric Alpha5 Smart Loader allows attackers to disclose sensitive information when parsing malicious files.","user_interaction":"not_required","vuln_class":"memory_corruption"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[{"product":"alpha5_smart_loader_firmware","vendor":"fujielectric"}],"cvss":{"score":5.3,"severity":"medium","source":"nvd","vector":"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N","version":"3.0"},"cwes":[{"id":"CWE-120","name":"Buffer Copy without Checking Size of Input"}],"description":"Fuji Electric Alpha5 Smart Loader Versions 3.7 and prior. A buffer overflow information disclosure vulnerability occurs when parsing certain file types.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Memory corruption in Alpha5 Smart Loader","id":"CVE-2018-14788","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"memory_corruption","year":"2018"},"n_packages":0,"n_references":2,"next":{"headline":"Privilege escalation in IntelliSpace Cardiovascular (ISCV) products","id":"CVE-2018-14789"},"packages":[],"prev":{"headline":"Privilege escalation in IntelliSpace Cardiovascular (ISCV) products","id":"CVE-2018-14787"},"products":["Alpha5 Smart Loader"],"published":"2018-10-01","related":[{"cvss_score":9.8,"headline":"Memory corruption in Alpha5 Smart Loader","id":"CVE-2018-14794","kev_date_added":null,"published":"2018-10-01"},{"cvss_score":7.8,"headline":"ICSA-22-090-03 Fuji Electric Alpha5","id":"CVE-2022-21214","kev_date_added":null,"published":"2022-04-12"},{"cvss_score":7.8,"headline":"ICSA-22-090-03 Fuji Electric Alpha5","id":"CVE-2022-21228","kev_date_added":null,"published":"2022-04-12"},{"cvss_score":7.8,"headline":"ICSA-22-090-03 Fuji Electric Alpha5","id":"CVE-2022-24383","kev_date_added":null,"published":"2022-04-12"},{"cvss_score":7.8,"headline":"Memory corruption in Alpha5 Smart Loader","id":"CVE-2019-13520","kev_date_added":null,"published":"2019-08-20"},{"cvss_score":3.3,"headline":"ICSA-22-090-03 Fuji Electric Alpha5","id":"CVE-2022-21168","kev_date_added":null,"published":"2022-04-12"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-09-17","vendors":["Fuji Electric"]},"summary":"A buffer overflow in Fuji Electric Alpha5 Smart Loader allows attackers to disclose sensitive information when parsing malicious files.","url":"https://insights.sbomify.com/CVE-2018-14788/"}