{"answers":{"affected":"It affects 5 products.","exploited":"There is no known exploitation of CVE-2018-14801 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2018-14801 yet. Limit exposure of the affected software until one is available.","what":"CVE-2018-14801 is a medium-severity vulnerability in Philips PageWriter TC10, TC20, TC30, TC50, TC70 Cardiographs, published on 22 Aug 2018. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2018-14801 and fix it if it is affected.\n\nWhat it is: CVE-2018-14801 is a medium-severity vulnerability in Philips PageWriter TC10, TC20, TC30, TC50, TC70 Cardiographs, published on 22 Aug 2018. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2018-14801 in the wild and no public exploit code.\n\nAffected product: Philips PageWriter TC10, TC20, TC30, TC50, TC70 Cardiographs. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2018-14801/ (Markdown: https://insights.sbomify.com/CVE-2018-14801/index.md)","id":"CVE-2018-14801","markdown":"https://insights.sbomify.com/CVE-2018-14801/index.md","name":"CVE-2018-14801","record":{"aliases":["GHSA-v52g-8mcm-r52h"],"analysis":{"component_type":"iot_embedded","fix_type":"patch","impacts":["privilege_escalation","data_modify"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Philips cardiograph","requires_auth":"high_privilege","summary":"Attackers with physical access and the superuser password can modify device settings and reset passwords on Philips cardiographs.","user_interaction":"not_required","vuln_class":"hardcoded_credentials"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[{"product":"pagewriter_tc10_firmware","vendor":"philips"},{"product":"pagewriter_tc20_firmware","vendor":"philips"},{"product":"pagewriter_tc30_firmware","vendor":"philips"},{"product":"pagewriter_tc50_firmware","vendor":"philips"},{"product":"pagewriter_tc70_firmware","vendor":"philips"}],"cvss":{"score":6.2,"severity":"medium","source":"nvd","vector":"CVSS:3.0/AV:P/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H","version":"3.0"},"cwes":[{"id":"CWE-798","name":"Use of Hard-coded Credentials"}],"description":"In Philips PageWriter TC10, TC20, TC30, TC50, TC70 Cardiographs, all versions prior to May 2018, an attacker with both the superuser password and physical access can enter the superuser password that can be used to access and modify all settings on the device, as well as allow the user to reset existing passwords.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Hardcoded credentials in PageWriter TC10, TC20, TC30, TC50, TC70 Cardiographs","id":"CVE-2018-14801","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"hardcoded_credentials","year":"2018"},"n_packages":0,"n_references":3,"next":{"headline":"Memory corruption in FRENIC LOADER of FRENIC-Mini (C1), FRENIC-Mini (C2), FRENIC-Eco, FRENIC-Multi, FRENIC-MEGA, FRENIC-Ace","id":"CVE-2018-14802"},"packages":[],"prev":{"headline":"Memory corruption in ISPSoft","id":"CVE-2018-14800"},"products":["PageWriter TC10, TC20, TC30, TC50, TC70 Cardiographs"],"published":"2018-08-22","related":[{"cvss_score":3.7,"headline":"Memory corruption in PageWriter TC10, TC20, TC30, TC50, TC70 Cardiographs","id":"CVE-2018-14799","kev_date_added":null,"published":"2018-08-22"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-09-17","vendors":["Philips"]},"summary":"Attackers with physical access and the superuser password can modify device settings and reset passwords on Philips cardiographs.","url":"https://insights.sbomify.com/CVE-2018-14801/"}