{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2018-14803 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2018-14803 yet. Limit exposure of the affected software until one is available.","what":"CVE-2018-14803 is a medium-severity vulnerability in Philips e-Alert Unit (non-medical device), published on 26 Sep 2018. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2018-14803 and fix it if it is affected.\n\nWhat it is: CVE-2018-14803 is a medium-severity vulnerability in Philips e-Alert Unit (non-medical device), published on 26 Sep 2018. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2018-14803 in the wild and no public exploit code.\n\nAffected product: Philips e-Alert Unit (non-medical device). No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2018-14803/ (Markdown: https://insights.sbomify.com/CVE-2018-14803/index.md)","id":"CVE-2018-14803","markdown":"https://insights.sbomify.com/CVE-2018-14803/index.md","name":"CVE-2018-14803","record":{"aliases":["GHSA-fqf6-p438-3j73"],"analysis":{"component_type":"iot_embedded","fix_type":"patch","impacts":["data_read"],"network_reachable":"yes","non_default_config":false,"product_category":"Philips e-Alert Unit","requires_auth":"none","summary":"Attackers can obtain extraneous product information like OS and software components via HTTP response headers, aiding further attacks.","user_interaction":"not_required","vuln_class":"information_disclosure"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[{"product":"e-alert_firmware","vendor":"philips"}],"cvss":{"score":5.3,"severity":"medium","source":"nvd","vector":"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N","version":"3.0"},"cwes":[{"id":"CWE-200","name":"Exposure of Sensitive Information to an Unauthorized Actor"}],"description":"Philips e-Alert Unit (non-medical device), Version R2.1 and prior. The Philips e-Alert contains a banner disclosure vulnerability that could allow attackers to obtain extraneous product information, such as OS and software components, via the HTTP response header that is normally not available to the attacker, but might be useful information in an attack.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Information disclosure in e-Alert Unit (non-medical device)","id":"CVE-2018-14803","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"information_disclosure","year":"2018"},"n_packages":0,"n_references":3,"next":{"headline":"Code injection in AMS Device Manager","id":"CVE-2018-14804"},"packages":[],"prev":{"headline":"Memory corruption in FRENIC LOADER of FRENIC-Mini (C1), FRENIC-Mini (C2), FRENIC-Eco, FRENIC-Multi, FRENIC-MEGA, FRENIC-Ace","id":"CVE-2018-14802"},"products":["e-Alert Unit (non-medical device)"],"published":"2018-09-26","related":[{"cvss_score":9.8,"headline":"Code injection in e-Alert Unit (non-medical device)","id":"CVE-2018-8850","kev_date_added":null,"published":"2018-09-26"},{"cvss_score":9.8,"headline":"Hardcoded credentials in e-Alert Unit (non-medical device)","id":"CVE-2018-8856","kev_date_added":null,"published":"2018-09-26"},{"cvss_score":8.8,"headline":"Information disclosure in e-Alert Unit (non-medical device)","id":"CVE-2018-8842","kev_date_added":null,"published":"2018-09-26"},{"cvss_score":8.8,"headline":"Cross-site request forgery in e-Alert Unit (non-medical device)","id":"CVE-2018-8844","kev_date_added":null,"published":"2018-09-26"},{"cvss_score":8.8,"headline":"Auth bypass in e-Alert Unit (non-medical device)","id":"CVE-2018-8852","kev_date_added":null,"published":"2018-09-26"},{"cvss_score":7.5,"headline":"Misconfiguration in e-Alert Unit (non-medical device)","id":"CVE-2018-8848","kev_date_added":null,"published":"2018-09-26"},{"cvss_score":7.5,"headline":"Denial of service in e-Alert Unit (non-medical device)","id":"CVE-2018-8854","kev_date_added":null,"published":"2018-09-26"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-09-17","vendors":["Philips"]},"summary":"Attackers can obtain extraneous product information like OS and software components via HTTP response headers, aiding further attacks.","url":"https://insights.sbomify.com/CVE-2018-14803/"}