{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2018-18990 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2018-18990 yet. Limit exposure of the affected software until one is available.","what":"CVE-2018-18990 is a medium-severity path traversal vulnerability in ICS-CERT LCDS Laquis SCADA, published on 5 Feb 2019. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2018-18990 and fix it if it is affected.\n\nWhat it is: CVE-2018-18990 is a medium-severity path traversal vulnerability in ICS-CERT LCDS Laquis SCADA, published on 5 Feb 2019. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2018-18990 in the wild and no public exploit code.\n\nAffected product: ICS-CERT LCDS Laquis SCADA. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2018-18990/ (Markdown: https://insights.sbomify.com/CVE-2018-18990/index.md)","id":"CVE-2018-18990","markdown":"https://insights.sbomify.com/CVE-2018-18990/index.md","name":"CVE-2018-18990","record":{"aliases":["GHSA-qc28-vhj7-64xw"],"analysis":{"component_type":"ics_ot","fix_type":"upgrade","impacts":["data_read"],"network_reachable":"yes","non_default_config":false,"product_category":"SCADA system","requires_auth":"none","summary":"Attackers can exploit path traversal in LCDS Laquis SCADA to disclose sensitive information via the web server process.","user_interaction":"not_required","vuln_class":"path_traversal"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[{"product":"laquis_scada","vendor":"lcds"}],"cvss":{"score":5.3,"severity":"medium","source":"nvd","vector":"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N","version":"3.0"},"cwes":[{"id":"CWE-22","name":"Improper Limitation of a Pathname to a Restricted Directory"},{"id":"CWE-23","name":"Relative Path Traversal"}],"description":"LCDS Laquis SCADA prior to version 4.1.0.4150 allows a user-supplied path in file operations prior to proper validation. An attacker can leverage this vulnerability to disclose sensitive information under the context of the web server process.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Path traversal in LCDS Laquis SCADA","id":"CVE-2018-18990","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"path_traversal","year":"2018"},"n_packages":0,"n_references":2,"next":{"headline":"Cross-site scripting in SCADA WebServer","id":"CVE-2018-18991"},"packages":[],"prev":{"headline":"Use after free in CX-One (CX-Programmer and CX-Server)","id":"CVE-2018-18989"},"products":["LCDS Laquis SCADA"],"published":"2019-02-05","related":[{"cvss_score":9.8,"headline":"Missing authorization in LCDS Laquis SCADA","id":"CVE-2018-18996","kev_date_added":null,"published":"2019-02-05"},{"cvss_score":9.8,"headline":"Hardcoded credentials in LCDS Laquis SCADA","id":"CVE-2018-18998","kev_date_added":null,"published":"2019-02-05"},{"cvss_score":9.8,"headline":"Null dereference in LAquis SCADA","id":"CVE-2018-17893","kev_date_added":null,"published":"2018-10-17"},{"cvss_score":9.8,"headline":"Memory corruption in LAquis SCADA","id":"CVE-2018-17895","kev_date_added":null,"published":"2018-10-17"},{"cvss_score":9.8,"headline":"Integer overflow in n/a","id":"CVE-2018-17897","kev_date_added":null,"published":"2018-10-17"},{"cvss_score":9.3,"headline":"LCDS LAquis SCADA - Cross-site Scripting","id":"CVE-2021-32989","kev_date_added":null,"published":"2022-05-25"},{"cvss_score":8.8,"headline":"LCDS Laquis SCADA prior to version 4.1.0.4150 allows taking in user input without proper sanitation, which may allow an attacker to execute","id":"CVE-2018-18992","kev_date_added":null,"published":"2019-02-05"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-09-17","vendors":["ICS-CERT"]},"summary":"Attackers can exploit path traversal in LCDS Laquis SCADA to disclose sensitive information via the web server process.","url":"https://insights.sbomify.com/CVE-2018-18990/"}