{"answers":{"affected":"It affects 4 products.","exploited":"There is no known exploitation of CVE-2018-19010 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2018-19010 yet. Limit exposure of the affected software until one is available.","what":"CVE-2018-19010 is a medium-severity denial of service vulnerability in ICS-CERT Dr\u0026#195;\u0026#164;ger Infinity Delta, published on 28 Jan 2019. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2018-19010 and fix it if it is affected.\n\nWhat it is: CVE-2018-19010 is a medium-severity denial of service vulnerability in ICS-CERT Dr\u0026#195;\u0026#164;ger Infinity Delta, published on 28 Jan 2019. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2018-19010 in the wild and no public exploit code.\n\nAffected product: ICS-CERT Dr\u0026#195;\u0026#164;ger Infinity Delta. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2018-19010/ (Markdown: https://insights.sbomify.com/CVE-2018-19010/index.md)","id":"CVE-2018-19010","markdown":"https://insights.sbomify.com/CVE-2018-19010/index.md","name":"CVE-2018-19010","record":{"aliases":["GHSA-6c7p-wgw2-hw4j"],"analysis":{"component_type":"ics_ot","fix_type":"no_fix_stated","impacts":["denial_of_service"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Medical patient monitor","requires_auth":"none","summary":"An attacker can cause repeated reboots of Dräger Infinity patient monitors via malformed network packets, disrupting patient monitoring and network connectivity.","user_interaction":"not_required","vuln_class":"denial_of_service"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[{"product":"delta_xl_firmware","vendor":"draeger"},{"product":"infinity_delta_firmware","vendor":"draeger"},{"product":"infinity_explorer_c700_firmware","vendor":"draeger"},{"product":"kappa_firmware","vendor":"draeger"}],"cvss":{"score":6.5,"severity":"medium","source":"nvd","vector":"CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","version":"3.0"},"cwes":[{"id":"CWE-20","name":"Improper Input Validation"}],"description":"Drager Infinity Delta, Infinity Delta, all versions, Delta XL, all versions, Kappa, all version, and Infinity Explorer C700, all versions. A malformed network packet may cause the monitor to reboot. By repeatedly sending the malformed network packet, an attacker may be able to disrupt patient monitoring by causing the monitor to repeatedly reboot until it falls back to default configuration and loses network connectivity.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Denial of service in Dr\u0026#195;\u0026#164;ger Infinity Delta","id":"CVE-2018-19010","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"denial_of_service","year":"2018"},"n_packages":0,"n_references":2,"next":{"headline":"Code injection in CX-Supervisor","id":"CVE-2018-19011"},"packages":[],"prev":{"headline":"Information disclosure in Pilz PNOZmulti Configurator","id":"CVE-2018-19009"},"products":["Dr\u0026#195;\u0026#164;ger Infinity Delta"],"published":"2019-01-28","related":[{"cvss_score":7.8,"headline":"Security feature bypass in Dr\u0026#195;\u0026#164;ger Infinity Delta","id":"CVE-2018-19012","kev_date_added":null,"published":"2019-01-28"},{"cvss_score":7.1,"headline":"Dräger Infinity Delta/Kappa Patient Monitor DoS via Malformed Network Packet","id":"CVE-2019-25716","kev_date_added":null,"published":"2026-06-01"},{"cvss_score":6.5,"headline":"Information disclosure in Dr\u0026#195;\u0026#164;ger Infinity Delta","id":"CVE-2018-19014","kev_date_added":null,"published":"2019-01-28"},{"cvss_score":5.3,"headline":"Dräger Infinity Delta/Kappa Patient Monitors Unauthenticated Log File Disclosure","id":"CVE-2019-25717","kev_date_added":null,"published":"2026-06-02"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-09-16","vendors":["ICS-CERT"]},"summary":"An attacker can cause repeated reboots of Dräger Infinity patient monitors via malformed network packets, disrupting patient monitoring and network connectivity.","url":"https://insights.sbomify.com/CVE-2018-19010/"}