{"answers":{"affected":"It affects 4 products.","exploited":"There is no known exploitation of CVE-2018-19014 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2018-19014 yet. Limit exposure of the affected software until one is available.","what":"CVE-2018-19014 is a medium-severity vulnerability in ICS-CERT Dr\u0026#195;\u0026#164;ger Infinity Delta, published on 28 Jan 2019. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2018-19014 and fix it if it is affected.\n\nWhat it is: CVE-2018-19014 is a medium-severity vulnerability in ICS-CERT Dr\u0026#195;\u0026#164;ger Infinity Delta, published on 28 Jan 2019. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2018-19014 in the wild and no public exploit code.\n\nAffected product: ICS-CERT Dr\u0026#195;\u0026#164;ger Infinity Delta. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2018-19014/ (Markdown: https://insights.sbomify.com/CVE-2018-19014/index.md)","id":"CVE-2018-19014","markdown":"https://insights.sbomify.com/CVE-2018-19014/index.md","name":"CVE-2018-19014","record":{"aliases":["GHSA-j27r-78g6-gwxh"],"analysis":{"component_type":"ics_ot","fix_type":"no_fix_stated","impacts":["data_read"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Patient monitoring system","requires_auth":"none","summary":"Unauthenticated attackers can access log files on Dräger patient monitors, revealing internal system details, location, and network configuration.","user_interaction":"not_required","vuln_class":"information_disclosure"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[{"product":"delta_xl_firmware","vendor":"draeger"},{"product":"infinity_delta_firmware","vendor":"draeger"},{"product":"infinity_explorer_c700_firmware","vendor":"draeger"},{"product":"kappa_firmware","vendor":"draeger"}],"cvss":{"score":6.5,"severity":"medium","source":"nvd","vector":"CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","version":"3.0"},"cwes":[{"id":"CWE-532","name":"Insertion of Sensitive Information into Log File"}],"description":"Drager Infinity Delta, Infinity Delta, all versions, Delta XL, all versions, Kappa, all version, and Infinity Explorer C700, all versions. Log files are accessible over an unauthenticated network connection. By accessing the log files, an attacker is able to gain insights about internals of the patient monitor, the location of the monitor, and wired network configuration.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Information disclosure in Dr\u0026#195;\u0026#164;ger Infinity Delta","id":"CVE-2018-19014","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"information_disclosure","year":"2018"},"n_packages":0,"n_references":2,"next":{"headline":"Command injection in CX-Supervisor","id":"CVE-2018-19015"},"packages":[],"prev":{"headline":"Command injection in CX-Supervisor","id":"CVE-2018-19013"},"products":["Dr\u0026#195;\u0026#164;ger Infinity Delta"],"published":"2019-01-28","related":[{"cvss_score":7.8,"headline":"Security feature bypass in Dr\u0026#195;\u0026#164;ger Infinity Delta","id":"CVE-2018-19012","kev_date_added":null,"published":"2019-01-28"},{"cvss_score":7.1,"headline":"Dräger Infinity Delta/Kappa Patient Monitor DoS via Malformed Network Packet","id":"CVE-2019-25716","kev_date_added":null,"published":"2026-06-01"},{"cvss_score":6.5,"headline":"Denial of service in Dr\u0026#195;\u0026#164;ger Infinity Delta","id":"CVE-2018-19010","kev_date_added":null,"published":"2019-01-28"},{"cvss_score":5.3,"headline":"Dräger Infinity Delta/Kappa Patient Monitors Unauthenticated Log File Disclosure","id":"CVE-2019-25717","kev_date_added":null,"published":"2026-06-02"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-09-16","vendors":["ICS-CERT"]},"summary":"Unauthenticated attackers can access log files on Dräger patient monitors, revealing internal system details, location, and network configuration.","url":"https://insights.sbomify.com/CVE-2018-19014/"}