{"answers":{"affected":"It affects 2 products.","exploited":"There is no known exploitation of CVE-2018-19394 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2018-19394 yet. Limit exposure of the affected software until one is available.","what":"CVE-2018-19394 is a medium-severity cross-site scripting vulnerability in n/a, published on 15 Mar 2019. An attacker needs administrator access to exploit it, and only if a user opens a file or follows a link."},"fix_prompt":"Check this codebase for CVE-2018-19394 and fix it if it is affected.\n\nWhat it is: CVE-2018-19394 is a medium-severity cross-site scripting vulnerability in n/a, published on 15 Mar 2019. An attacker needs administrator access to exploit it, and only if a user opens a file or follows a link.\nExploitation: There is no known exploitation of CVE-2018-19394 in the wild and no public exploit code.\n\nAffected product: n/a. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2018-19394/ (Markdown: https://insights.sbomify.com/CVE-2018-19394/index.md)","id":"CVE-2018-19394","markdown":"https://insights.sbomify.com/CVE-2018-19394/index.md","name":"CVE-2018-19394","record":{"aliases":["GHSA-8363-pjm5-wqcw"],"analysis":{"component_type":"network_device","fix_type":"patch","impacts":["code_execution","account_takeover"],"network_reachable":"yes","non_default_config":false,"product_category":"Satcom terminal","requires_auth":"high_privilege","summary":"Attackers with admin access can inject persistent XSS via configuration files in Cobham Satcom devices, potentially leading to code execution or account takeover.","user_interaction":"required","vuln_class":"xss"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"mitre","cpe":[{"product":"satcom_sailor_800_firmware","vendor":"cobham"},{"product":"satcom_sailor_900_firmware","vendor":"cobham"}],"cvss":{"score":4.8,"severity":"medium","source":"nvd","vector":"CVSS:3.0/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N","version":"3.0"},"cwes":[{"id":"CWE-79","name":"Improper Neutralization of Input During Web Page Generation"}],"description":"Cobham Satcom Sailor 800 and 900 devices contained persistent XSS, which required administrative access to exploit. The vulnerability was exploitable by acquiring a copy of the device's configuration file, inserting an XSS payload into a relevant field (e.g., Satellite name), and then restoring the malicious configuration file.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Cross-site scripting in n/a","id":"CVE-2018-19394","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"xss","year":"2018"},"n_packages":0,"n_references":2,"next":{"headline":"Null dereference in n/a","id":"CVE-2018-19395"},"packages":[],"prev":{"headline":"Missing authorization in n/a","id":"CVE-2018-19393"},"products":["n/a"],"published":"2019-03-15","related":[{"cvss_score":7.5,"headline":"Missing authorization in n/a","id":"CVE-2018-19393","kev_date_added":null,"published":"2019-03-15"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-05","vendors":["n/a"]},"summary":"Attackers with admin access can inject persistent XSS via configuration files in Cobham Satcom devices, potentially leading to code execution or account takeover.","url":"https://insights.sbomify.com/CVE-2018-19394/"}