{"answers":{"affected":"","exploited":"It is not confirmed as exploited in the wild, but public exploit code for CVE-2018-25140 exists.","fix":"No fix has been published for CVE-2018-25140 yet. Limit exposure of the affected software until one is available.","what":"CVE-2018-25140 is a critical authentication bypass vulnerability in FLIR Systems, Inc. Thermal Traffic Cameras, published on 24 Dec 2025. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2018-25140 and fix it if it is affected.\n\nWhat it is: CVE-2018-25140 is a critical authentication bypass vulnerability in FLIR Systems, Inc. Thermal Traffic Cameras, published on 24 Dec 2025. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: It is not confirmed as exploited in the wild, but public exploit code for CVE-2018-25140 exists.\n\nAffected product: FLIR Systems, Inc. Thermal Traffic Cameras. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2018-25140/ (Markdown: https://insights.sbomify.com/CVE-2018-25140/index.md)","id":"CVE-2018-25140","markdown":"https://insights.sbomify.com/CVE-2018-25140/index.md","name":"CVE-2018-25140","record":{"aliases":["GHSA-h2gq-4xqf-ccqf"],"analysis":{"component_type":"iot_embedded","fix_type":"no_fix_stated","impacts":["data_modify","denial_of_service"],"network_reachable":"yes","non_default_config":false,"product_category":"Thermal Traffic Camera","requires_auth":"none","summary":"Unauthenticated attackers can manipulate FLIR thermal traffic cameras via WebSocket to modify configurations, access system info, or cause denial of service.","user_interaction":"not_required","vuln_class":"auth_bypass"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"VulnCheck","cpe":[],"cvss":{"score":9.3,"severity":"critical","source":"cna","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","version":"4.0"},"cwes":[{"id":"CWE-306","name":"Missing Authentication for Critical Functionality"}],"description":"FLIR thermal traffic cameras contain an unauthenticated device manipulation vulnerability in their WebSocket implementation that allows attackers to bypass authentication and authorization controls. Attackers can directly modify device configurations, access system information, and potentially initiate denial of service by sending crafted WebSocket messages without authentication.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"weaponised"},"has_fix":null,"headline":"FLIR Thermal Traffic Cameras V1.01-0bb5b27 Unauthenticated Websocket Device Manipulation","id":"CVE-2018-25140","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"auth_bypass","year":"2018"},"n_packages":0,"n_references":3,"next":{"headline":"FLIR Thermal Traffic Cameras V1.01-0bb5b27 Unauthenticated RTSP Stream Disclosure","id":"CVE-2018-25141"},"packages":[],"prev":{"headline":"FLIR AX8 Thermal Camera 1.32.16 Unauthenticated RTSP Stream Disclosure","id":"CVE-2018-25139"},"products":["Thermal Traffic Cameras"],"published":"2025-12-24","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"yes","exploitation":"poc","technical_impact":"total"},"state":"PUBLISHED","updated":"2025-12-24","vendors":["FLIR Systems, Inc."]},"summary":"Unauthenticated attackers can manipulate FLIR thermal traffic cameras via WebSocket to modify configurations, access system info, or cause denial of service.","url":"https://insights.sbomify.com/CVE-2018-25140/"}