{"answers":{"affected":"It affects 5 products.","exploited":"There is no known exploitation of CVE-2018-4834 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2018-4834 yet. Limit exposure of the affected software until one is available.","what":"CVE-2018-4834 is a critical vulnerability in Siemens Desigo PXC00-E.D V4.10, published on 24 Jan 2018. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2018-4834 and fix it if it is affected.\n\nWhat it is: CVE-2018-4834 is a critical vulnerability in Siemens Desigo PXC00-E.D V4.10, published on 24 Jan 2018. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2018-4834 in the wild and no public exploit code.\n\nAffected product: Siemens Desigo PXC00-E.D V4.10. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2018-4834/ (Markdown: https://insights.sbomify.com/CVE-2018-4834/index.md)","id":"CVE-2018-4834","markdown":"https://insights.sbomify.com/CVE-2018-4834/index.md","name":"CVE-2018-4834","record":{"aliases":["GHSA-6764-3gh7-vvcp"],"analysis":{"component_type":"ics_ot","fix_type":"upgrade","impacts":["code_execution"],"network_reachable":"yes","non_default_config":false,"product_category":"Siemens Desigo controller","requires_auth":"none","summary":"An attacker can upload malicious files to Siemens Desigo controllers, potentially leading to remote code execution.","user_interaction":"not_required","vuln_class":"file_upload"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"siemens","cpe":[{"product":"pxc001-e.d_firmware","vendor":"siemens"},{"product":"pxc00\\/50\\/100\\/200-e.d_firmware","vendor":"siemens"},{"product":"pxc00\\/64\\/128-u_firmware","vendor":"siemens"},{"product":"pxc12\\/22\\/36-e.d_firmware","vendor":"siemens"},{"product":"pxm20-e_firmware","vendor":"siemens"}],"cvss":{"score":9.8,"severity":"critical","source":"cna","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C","version":"3.1"},"cwes":[{"id":"CWE-434","name":"Unrestricted Upload of File with Dangerous Type"},{"id":"CWE-306","name":"Missing Authentication for Critical Functionality"}],"description":"A vulnerability has been identified in Desigo PXC00-E.D V4.10 (All versions \u003c V4.10.111), Desigo PXC00-E.D V5.00 (All versions \u003c V5.0.171), Desigo PXC00-E.D V5.10 (All versions \u003c V5.10.69), Desigo PXC00-E.D V6.00 (All versions \u003c V6.0.204), Desigo PXC00/64/128-U V4.10 (All versions \u003c V4.10.111 only with web module), Desigo PXC00/64/128-U V5.00 (All versions \u003c V5.0.171 only with web module), Desigo PXC00/64/128-U V5.10 (All versions \u003c V5.10.69 only with web module), Desigo PXC00/64/128-U V6.00 (All versions \u003c V6.0.204 only with web module), Desigo PXC001-E.D V4.10 (All versions \u003c V4.10.111), Desigo PXC001-E.D V5.00 (All versions \u003c V5.0.171), Desigo PXC001-E.D V5.10 (All versions \u003c V5.10.69), Desigo PXC001-E.D V6.00 (All versions \u003c V6.0.204), Desigo PXC100-E.D V4.10 (All versions \u003c V4.10.111), Desigo PXC100-E.D V5.00 (All versions \u003c V5.0.171), Desigo PXC100-E.D V5.10 (All versions \u003c V5.10.69), Desigo PXC100-E.D V6.00 (All versions \u003c V6.0.204), Desigo PXC12-E.D V4.10 (All versions \u003c V4.10.111), Desigo PXC12-E.D V5.00 (All versions \u003c V5.0.171), Desigo PXC12-E.D V5.10 (All versions \u003c V5.10.69), Desigo PXC12-E.D V6.00 (All versions \u003c V6.0.204), Desigo PXC200-E.D V4.10 (All versions \u003c V4.10.111), Desigo PXC200-E.D V5.00 (All versions \u003c V5.0.171), Desigo PXC200-E.D V5.10 (All versions \u003c V5.10.69), Desigo PXC200-E.D V6.00 (All versions \u003c V6.0.204), Desigo PXC22-E.D V4.10 (All versions \u003c V4.10.111), Desigo PXC22-E.D V5.00 (All versions \u003c V5.0.171), Desigo PXC22-E.D V5.10 (All versions \u003c V5.10.69), Desigo PXC22-E.D V6.00 (All versions \u003c V6.0.204), Desigo PXC22.1-E.D V4.10 (All versions \u003c V4.10.111), Desigo PXC22.1-E.D V5.00 (All versions \u003c V5.0.171), Desigo PXC22.1-E.D V5.10 (All versions \u003c V5.10.69), Desigo PXC22.1-E.D V6.00 (All versions \u003c V6.0.204), Desigo PXC36.1-E.D V4.10 (All versions \u003c V4.10.111), Desigo PXC36.1-E.D V5.00 (All versions \u003c V5.0.171), Desigo PXC36.1-E.D V5.10 (All versions \u003c V5.10.69), Desigo PXC36.1-E.D V6.00 (All versions \u003c V6.0.204), Desigo PXC50-E.D V4.10 (All versions \u003c V4.10.111), Desigo PXC50-E.D V5.00 (All versions \u003c V5.0.171), Desigo PXC50-E.D V5.10 (All versions \u003c V5.10.69), Desigo PXC50-E.D V6.00 (All versions \u003c V6.0.204), Desigo PXM20-E V4.10 (All versions \u003c V4.10.111), Desigo PXM20-E V5.00 (All versions \u003c V5.0.171), Desigo PXM20-E V5.10 (All versions \u003c V5.10.69), Desigo PXM20-E V6.00 (All versions \u003c V6.0.204). A remote attacker with network access to the device could potentially upload a new firmware image to the devices without prior authentication.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"File upload in Desigo PXC00-E.D V4.10","id":"CVE-2018-4834","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"file_upload","year":"2018"},"n_packages":0,"n_references":1,"next":{"headline":"Auth bypass in TeleControl Server Basic","id":"CVE-2018-4835"},"packages":[],"prev":{"headline":"Memory corruption in RFID 181EIP","id":"CVE-2018-4833"},"products":["Desigo PXC00-E.D V4.10","Desigo PXC00-E.D V5.00","Desigo PXC00-E.D V5.10","Desigo PXC00-E.D V6.00","Desigo PXC00/64/128-U V4.10","Desigo PXC00/64/128-U V5.00","Desigo PXC00/64/128-U V5.10","Desigo PXC00/64/128-U V6.00","Desigo PXC001-E.D V4.10","Desigo PXC001-E.D V5.00","Desigo PXC001-E.D V5.10","Desigo PXC001-E.D V6.00","Desigo PXC100-E.D V4.10","Desigo PXC100-E.D V5.00","Desigo PXC100-E.D V5.10","Desigo PXC100-E.D V6.00","Desigo PXC12-E.D V4.10","Desigo PXC12-E.D V5.00","Desigo PXC12-E.D V5.10","Desigo PXC12-E.D V6.00","Desigo PXC200-E.D V4.10","Desigo PXC200-E.D V5.00","Desigo PXC200-E.D V5.10","Desigo PXC200-E.D V6.00","Desigo PXC22-E.D V4.10","Desigo PXC22-E.D V5.00","Desigo PXC22-E.D V5.10","Desigo PXC22-E.D V6.00","Desigo PXC22.1-E.D V4.10","Desigo PXC22.1-E.D V5.00","Desigo PXC22.1-E.D V5.10","Desigo PXC22.1-E.D V6.00","Desigo PXC36.1-E.D V4.10","Desigo PXC36.1-E.D V5.00","Desigo PXC36.1-E.D V5.10","Desigo PXC36.1-E.D V6.00","Desigo PXC50-E.D V4.10","Desigo PXC50-E.D V5.00","Desigo PXC50-E.D V5.10","Desigo PXC50-E.D V6.00","Desigo PXM20-E V4.10","Desigo PXM20-E V5.00","Desigo PXM20-E V5.10","Desigo PXM20-E V6.00"],"published":"2018-01-24","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-09-17","vendors":["Siemens"]},"summary":"An attacker can upload malicious files to Siemens Desigo controllers, potentially leading to remote code execution.","url":"https://insights.sbomify.com/CVE-2018-4834/"}