{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2018-4844 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2018-4844 yet. Limit exposure of the affected software until one is available.","what":"CVE-2018-4844 is a medium-severity vulnerability in Siemens AG SIMATIC WinCC OA UI for Android, SIMATIC WinCC OA UI for iOS, published on 20 Mar 2018."},"fix_prompt":"Check this codebase for CVE-2018-4844 and fix it if it is affected.\n\nWhat it is: CVE-2018-4844 is a medium-severity vulnerability in Siemens AG SIMATIC WinCC OA UI for Android, SIMATIC WinCC OA UI for iOS, published on 20 Mar 2018. \nExploitation: There is no known exploitation of CVE-2018-4844 in the wild and no public exploit code.\n\nAffected product: Siemens AG SIMATIC WinCC OA UI for Android, SIMATIC WinCC OA UI for iOS. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2018-4844/ (Markdown: https://insights.sbomify.com/CVE-2018-4844/index.md)","id":"CVE-2018-4844","markdown":"https://insights.sbomify.com/CVE-2018-4844/index.md","name":"CVE-2018-4844","record":{"aliases":["GHSA-2w26-vhm9-x8ph"],"analysis":null,"analysis_generated_by":null,"assigner":"siemens","cpe":[{"product":"simatic_wincc_oa_ui","vendor":"siemens"}],"cvss":{"score":6.7,"severity":"medium","source":"nvd","vector":"CVSS:3.1/AV:A/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:N","version":"3.1"},"cwes":[{"id":"CWE-269","name":"Improper Privilege Management"},{"id":"CWE-284","name":"Improper Access Control"}],"description":"A vulnerability has been identified in SIMATIC WinCC OA UI for Android (All versions \u003c V3.15.10), SIMATIC WinCC OA UI for iOS (All versions \u003c V3.15.10). Insufficient limitation of CONTROL script capabilities could allow read and write access from one HMI project cache folder to other HMI project cache folders within the app's sandbox on the same mobile device. This includes HMI project cache folders of other configured WinCC OA servers. The security vulnerability could be exploited by an attacker who tricks an app user to connect to an attacker-controlled WinCC OA server. Successful exploitation requires user interaction and read/write access to the app's folder on a mobile device. The vulnerability could allow reading data from and writing data to the app's folder. At the time of advisory publication no public exploitation of this security vulnerability was known. Siemens confirms the security vulnerability and provides mitigations to resolve the security issue.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"A vulnerability has been identified in SIMATIC WinCC OA UI for Android (All versions \u003c V3.15.10), SIMATIC WinCC OA UI for iOS (All versions \u003c V3.15.10).","id":"CVE-2018-4844","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":null,"year":"2018"},"n_packages":0,"n_references":2,"next":{"headline":"Privilege escalation in RAPIDLab 1200 systems / RAPIDPoint 400 systems / RAPIDPoint 500 systems, RAPIDLab 1200 Series, RAPIDPoint 500 systems, RAPIDPoint 500 systems, RAPIDPoint 500 systems, RAPIDPoint 400 systems","id":"CVE-2018-4845"},"packages":[],"prev":{"headline":"Other in SIMATIC CP 343-1 (incl. SIPLUS variants)","id":"CVE-2018-4843"},"products":["SIMATIC WinCC OA UI for Android, SIMATIC WinCC OA UI for iOS"],"published":"2018-03-20","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-09-17","vendors":["Siemens AG"]},"summary":null,"url":"https://insights.sbomify.com/CVE-2018-4844/"}