{"answers":{"affected":"It affects 2 products.","exploited":"There is no known exploitation of CVE-2018-6021 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2018-6021 yet. Limit exposure of the affected software until one is available.","what":"CVE-2018-6021 is a high-severity command injection vulnerability in n/a, published on 9 May 2018. Any signed-in user can exploit it over the network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2018-6021 and fix it if it is affected.\n\nWhat it is: CVE-2018-6021 is a high-severity command injection vulnerability in n/a, published on 9 May 2018. Any signed-in user can exploit it over the network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2018-6021 in the wild and no public exploit code.\n\nAffected product: n/a. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2018-6021/ (Markdown: https://insights.sbomify.com/CVE-2018-6021/index.md)","id":"CVE-2018-6021","markdown":"https://insights.sbomify.com/CVE-2018-6021/index.md","name":"CVE-2018-6021","record":{"aliases":["GHSA-pw4x-2ppx-26rp"],"analysis":{"component_type":"iot_embedded","fix_type":"no_fix_stated","impacts":["code_execution"],"network_reachable":"yes","non_default_config":false,"product_category":"Smart Home Device","requires_auth":"low_privilege","summary":"Attackers can execute arbitrary code remotely on Silex and GE smart home devices due to unsanitized system call parameters.","user_interaction":"not_required","vuln_class":"command_injection"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"mitre","cpe":[{"product":"geh-sd-320an_firmware","vendor":"silextechnology"},{"product":"sd-320an_firmware","vendor":"silextechnology"}],"cvss":{"score":7.4,"severity":"high","source":"nvd","vector":"CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:C/C:L/I:L/A:L","version":"3.0"},"cwes":[{"id":"CWE-78","name":"Improper Neutralization of Special Elements used in an OS Command"}],"description":"Silex SD-320AN version 2.01 and prior and GE MobileLink(GEH-SD-320AN) version GEH-1.1 and prior have a system call parameter that is not properly sanitized, which may allow remote code execution.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Command injection in n/a","id":"CVE-2018-6021","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"command_injection","year":"2018"},"n_packages":0,"n_references":1,"next":{"headline":"Path traversal in n/a","id":"CVE-2018-6022"},"packages":[],"prev":{"headline":"Auth bypass in n/a","id":"CVE-2018-6020"},"products":["n/a"],"published":"2018-05-09","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-09-16","vendors":["n/a"]},"summary":"Attackers can execute arbitrary code remotely on Silex and GE smart home devices due to unsanitized system call parameters.","url":"https://insights.sbomify.com/CVE-2018-6021/"}