{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2018-7074 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2018-7074 yet. Limit exposure of the affected software until one is available.","what":"CVE-2018-7074 is a critical code injection vulnerability in Hp Intelligent Management Center, published on 6 Aug 2018. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2018-7074 and fix it if it is affected.\n\nWhat it is: CVE-2018-7074 is a critical code injection vulnerability in Hp Intelligent Management Center, published on 6 Aug 2018. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2018-7074 in the wild and no public exploit code.\n\nAffected product: Hp Intelligent Management Center. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2018-7074/ (Markdown: https://insights.sbomify.com/CVE-2018-7074/index.md)","id":"CVE-2018-7074","markdown":"https://insights.sbomify.com/CVE-2018-7074/index.md","name":"CVE-2018-7074","record":{"aliases":["GHSA-rpgg-xqp6-2g22"],"analysis":{"component_type":"server_software","fix_type":"upgrade","impacts":["code_execution"],"network_reachable":"yes","non_default_config":false,"product_category":"Network management software","requires_auth":"none","summary":"Remote attackers can execute arbitrary code on HPE Intelligent Management Center servers, requiring an upgrade to a patched version.","user_interaction":"not_required","vuln_class":"code_injection"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"hpe","cpe":[{"product":"intelligent_management_center","vendor":"hp"}],"cvss":{"score":9.8,"severity":"critical","source":"nvd","vector":"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","version":"3.0"},"cwes":[],"description":"A remote code execution vulnerability was identified in HPE Intelligent Management Center (iMC) PLAT 7.3 E0506P07. The vulnerability was resolved in iMC PLAT 7.3 E0605P04 or subsequent version.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Code injection in HPE Intelligent Management Center (IMC)","id":"CVE-2018-7074","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":"hp:intelligent_management_center","products":["hp:intelligent_management_center"],"type":"code_injection","year":"2018"},"n_packages":0,"n_references":2,"next":{"headline":"Cross-site scripting in HPE Intelligent Management Center (IMC)","id":"CVE-2018-7075"},"packages":[],"prev":{"headline":"Path traversal in HPE Moonshot Provisioning Manager","id":"CVE-2018-7073"},"products":["HPE Intelligent Management Center (IMC)"],"published":"2018-08-06","related":[{"cvss_score":10,"headline":"Code injection in n/a","id":"CVE-2012-5201","kev_date_added":null,"published":"2013-03-09"},{"cvss_score":10,"headline":"Other in n/a","id":"CVE-2012-5209","kev_date_added":null,"published":"2013-03-09"},{"cvss_score":10,"headline":"Memory corruption in n/a","id":"CVE-2012-3274","kev_date_added":null,"published":"2012-12-06"},{"cvss_score":10,"headline":"Memory corruption in n/a","id":"CVE-2012-3253","kev_date_added":null,"published":"2012-08-30"},{"cvss_score":10,"headline":"Integer overflow in n/a","id":"CVE-2011-2331","kev_date_added":null,"published":"2011-06-02"},{"cvss_score":10,"headline":"Memory corruption in n/a","id":"CVE-2011-1848","kev_date_added":null,"published":"2011-05-13"},{"cvss_score":10,"headline":"File upload in n/a","id":"CVE-2011-1849","kev_date_added":null,"published":"2011-05-13"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-05","vendors":["Hewlett Packard Enterprise"]},"summary":"Remote attackers can execute arbitrary code on HPE Intelligent Management Center servers, requiring an upgrade to a patched version.","url":"https://insights.sbomify.com/CVE-2018-7074/"}