{"answers":{"affected":"It affects 20 products.","exploited":"There is no known exploitation of CVE-2018-7229 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2018-7229 yet. Limit exposure of the affected software until one is available.","what":"CVE-2018-7229 is a critical vulnerability in Schneider Electric SE Pelco Sarix Professional, published on 9 Mar 2018. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2018-7229 and fix it if it is affected.\n\nWhat it is: CVE-2018-7229 is a critical vulnerability in Schneider Electric SE Pelco Sarix Professional, published on 9 Mar 2018. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2018-7229 in the wild and no public exploit code.\n\nAffected product: Schneider Electric SE Pelco Sarix Professional. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2018-7229/ (Markdown: https://insights.sbomify.com/CVE-2018-7229/index.md)","id":"CVE-2018-7229","markdown":"https://insights.sbomify.com/CVE-2018-7229/index.md","name":"CVE-2018-7229","record":{"aliases":["GHSA-gh8q-9q7p-q94j"],"analysis":{"component_type":"iot_embedded","fix_type":"upgrade","impacts":["privilege_escalation","account_takeover"],"network_reachable":"yes","non_default_config":false,"product_category":"Pelco Sarix Professional","requires_auth":"none","summary":"Unauthenticated attackers can bypass authentication and gain administrator privileges due to hardcoded credentials in Pelco Sarix Professional cameras.","user_interaction":"not_required","vuln_class":"hardcoded_credentials"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"schneider","cpe":[{"product":"ibp1110-1er_firmware","vendor":"schneider-electric"},{"product":"ibp219-1er_firmware","vendor":"schneider-electric"},{"product":"ibp319-1er_firmware","vendor":"schneider-electric"},{"product":"ibp519-1er_firmware","vendor":"schneider-electric"},{"product":"ibps110-1er_firmware","vendor":"schneider-electric"},{"product":"imp1110-1_firmware","vendor":"schneider-electric"},{"product":"imp1110-1e_firmware","vendor":"schneider-electric"},{"product":"imp1110-1er_firmware","vendor":"schneider-electric"},{"product":"imp219-1_firmware","vendor":"schneider-electric"},{"product":"imp219-1e_firmware","vendor":"schneider-electric"},{"product":"imp219-1er_firmware","vendor":"schneider-electric"},{"product":"imp319-1_firmware","vendor":"schneider-electric"},{"product":"imp319-1e_firmware","vendor":"schneider-electric"},{"product":"imp319-1er_firmware","vendor":"schneider-electric"},{"product":"imp519-1_firmware","vendor":"schneider-electric"},{"product":"imp519-1e_firmware","vendor":"schneider-electric"},{"product":"imp519-1er_firmware","vendor":"schneider-electric"},{"product":"imps110-1e_firmware","vendor":"schneider-electric"},{"product":"imps110-1er_firmware","vendor":"schneider-electric"},{"product":"mps110-1_firmware","vendor":"schneider-electric"}],"cvss":{"score":9.8,"severity":"critical","source":"nvd","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"cwes":[{"id":"CWE-798","name":"Use of Hard-coded Credentials"}],"description":"A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow an unauthenticated, remote attacker to bypass authentication and gain administrator privileges because the use of hardcoded credentials.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Hardcoded credentials in Pelco Sarix Professional","id":"CVE-2018-7229","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"hardcoded_credentials","year":"2018"},"n_packages":0,"n_references":1,"next":{"headline":"XML external entity in Pelco Sarix Professional","id":"CVE-2018-7230"},"packages":[],"prev":{"headline":"Auth bypass in Pelco Sarix Professional","id":"CVE-2018-7228"},"products":["Pelco Sarix Professional"],"published":"2018-03-09","related":[{"cvss_score":9.8,"headline":"Memory corruption in Pelco Sarix Professional V1","id":"CVE-2018-7780","kev_date_added":null,"published":"2018-07-03"},{"cvss_score":9.8,"headline":"Auth bypass in Pelco Sarix Professional","id":"CVE-2018-7228","kev_date_added":null,"published":"2018-03-09"},{"cvss_score":9.8,"headline":"Command injection in Pelco Sarix Professional","id":"CVE-2018-7231","kev_date_added":null,"published":"2018-03-09"},{"cvss_score":9.8,"headline":"Command injection in Pelco Sarix Professional","id":"CVE-2018-7232","kev_date_added":null,"published":"2018-03-09"},{"cvss_score":9.8,"headline":"Command injection in Pelco Sarix Professional","id":"CVE-2018-7233","kev_date_added":null,"published":"2018-03-09"},{"cvss_score":9.8,"headline":"Memory corruption in Pelco Sarix Professional","id":"CVE-2018-7238","kev_date_added":null,"published":"2018-03-09"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-09-16","vendors":["Schneider Electric SE"]},"summary":"Unauthenticated attackers can bypass authentication and gain administrator privileges due to hardcoded credentials in Pelco Sarix Professional cameras.","url":"https://insights.sbomify.com/CVE-2018-7229/"}