{"answers":{"affected":"It affects 57 products.","exploited":"There is no known exploitation of CVE-2018-7241 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2018-7241 yet. Limit exposure of the affected software until one is available.","what":"CVE-2018-7241 is a critical vulnerability in Schneider Electric SE Modicon Premium, Modicon Quantum, Modicon M340, BMXNOR0200, published on 18 Apr 2018. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2018-7241 and fix it if it is affected.\n\nWhat it is: CVE-2018-7241 is a critical vulnerability in Schneider Electric SE Modicon Premium, Modicon Quantum, Modicon M340, BMXNOR0200, published on 18 Apr 2018. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2018-7241 in the wild and no public exploit code.\n\nAffected product: Schneider Electric SE Modicon Premium, Modicon Quantum, Modicon M340, BMXNOR0200. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2018-7241/ (Markdown: https://insights.sbomify.com/CVE-2018-7241/index.md)","id":"CVE-2018-7241","markdown":"https://insights.sbomify.com/CVE-2018-7241/index.md","name":"CVE-2018-7241","record":{"aliases":["GHSA-rhfc-jm87-h52j"],"analysis":{"component_type":"ics_ot","fix_type":"patch","impacts":["account_takeover","privilege_escalation"],"network_reachable":"yes","non_default_config":false,"product_category":"Schneider Electric PLC","requires_auth":"none","summary":"Hardcoded accounts in Schneider Electric Modicon controllers allow attackers to gain unauthorized access and control over industrial systems.","user_interaction":"not_required","vuln_class":"hardcoded_credentials"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"schneider","cpe":[{"product":"140cpu31110_firmware","vendor":"schneider-electric"},{"product":"140cpu31110c_firmware","vendor":"schneider-electric"},{"product":"140cpu43412u_firmware","vendor":"schneider-electric"},{"product":"140cpu43412uc_firmware","vendor":"schneider-electric"},{"product":"140cpu65150_firmware","vendor":"schneider-electric"},{"product":"140cpu65150c_firmware","vendor":"schneider-electric"},{"product":"140cpu65160_firmware","vendor":"schneider-electric"},{"product":"140cpu65160c_firmware","vendor":"schneider-electric"},{"product":"140cpu65160s_firmware","vendor":"schneider-electric"},{"product":"140cpu65260_firmware","vendor":"schneider-electric"},{"product":"140cpu65260c_firmware","vendor":"schneider-electric"},{"product":"140cpu65860_firmware","vendor":"schneider-electric"},{"product":"140cpu65860c_firmware","vendor":"schneider-electric"},{"product":"bmxnor0200_firmware","vendor":"schneider-electric"},{"product":"bmxnor0200h_firmware","vendor":"schneider-electric"},{"product":"modicon_m340_bmxp341000_firmware","vendor":"schneider-electric"},{"product":"modicon_m340_bmxp341000h_firmware","vendor":"schneider-electric"},{"product":"modicon_m340_bmxp342000_firmware","vendor":"schneider-electric"},{"product":"modicon_m340_bmxp3420102_firmware","vendor":"schneider-electric"},{"product":"modicon_m340_bmxp3420102cl_firmware","vendor":"schneider-electric"},{"product":"modicon_m340_bmxp342020_firmware","vendor":"schneider-electric"},{"product":"modicon_m340_bmxp342020h_firmware","vendor":"schneider-electric"},{"product":"modicon_m340_bmxp3420302_firmware","vendor":"schneider-electric"},{"product":"modicon_m340_bmxp3420302cl_firmware","vendor":"schneider-electric"},{"product":"modicon_m340_bmxp3420302h_firmware","vendor":"schneider-electric"},{"product":"tsxh5724m_firmware","vendor":"schneider-electric"},{"product":"tsxh5724mc_firmware","vendor":"schneider-electric"},{"product":"tsxh5744m_firmware","vendor":"schneider-electric"},{"product":"tsxh5744mc_firmware","vendor":"schneider-electric"},{"product":"tsxp57104m_firmware","vendor":"schneider-electric"},{"product":"tsxp57104mc_firmware","vendor":"schneider-electric"},{"product":"tsxp57154m_firmware","vendor":"schneider-electric"},{"product":"tsxp57154mc_firmware","vendor":"schneider-electric"},{"product":"tsxp571634m_firmware","vendor":"schneider-electric"},{"product":"tsxp571634mc_firmware","vendor":"schneider-electric"},{"product":"tsxp57204m_firmware","vendor":"schneider-electric"},{"product":"tsxp57204mc_firmware","vendor":"schneider-electric"},{"product":"tsxp57254m_firmware","vendor":"schneider-electric"},{"product":"tsxp57254mc_firmware","vendor":"schneider-electric"},{"product":"tsxp572634m_firmware","vendor":"schneider-electric"},{"product":"tsxp572634mc_firmware","vendor":"schneider-electric"},{"product":"tsxp57304m_firmware","vendor":"schneider-electric"},{"product":"tsxp57304mc_firmware","vendor":"schneider-electric"},{"product":"tsxp57354m_firmware","vendor":"schneider-electric"},{"product":"tsxp57354mc_firmware","vendor":"schneider-electric"},{"product":"tsxp573634m_firmware","vendor":"schneider-electric"},{"product":"tsxp573634mc_firmware","vendor":"schneider-electric"},{"product":"tsxp57454m_firmware","vendor":"schneider-electric"},{"product":"tsxp57454mc_firmware","vendor":"schneider-electric"},{"product":"tsxp574634m_firmware","vendor":"schneider-electric"},{"product":"tsxp574634mc_firmware","vendor":"schneider-electric"},{"product":"tsxp57554m_firmware","vendor":"schneider-electric"},{"product":"tsxp57554mc_firmware","vendor":"schneider-electric"},{"product":"tsxp575634m_firmware","vendor":"schneider-electric"},{"product":"tsxp575634mc_firmware","vendor":"schneider-electric"},{"product":"tsxp576634m_firmware","vendor":"schneider-electric"},{"product":"tsxp576634mc_firmware","vendor":"schneider-electric"}],"cvss":{"score":9.8,"severity":"critical","source":"nvd","vector":"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","version":"3.0"},"cwes":[{"id":"CWE-798","name":"Use of Hard-coded Credentials"}],"description":"Hard coded accounts exist in Schneider Electric's Modicon Premium, Modicon Quantum, Modicon M340, and BMXNOR0200 controllers in all versions of the communication modules.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Hardcoded credentials in Modicon Premium, Modicon Quantum, Modicon M340, BMXNOR0200","id":"CVE-2018-7241","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"hardcoded_credentials","year":"2018"},"n_packages":0,"n_references":3,"next":{"headline":"Weak cryptography in Modicon Premium, Modicon Quantum, Modicon M340, BMXNOR0200","id":"CVE-2018-7242"},"packages":[],"prev":{"headline":"Command injection in Modicon Quantum","id":"CVE-2018-7240"},"products":["Modicon Premium, Modicon Quantum, Modicon M340, BMXNOR0200"],"published":"2018-04-18","related":[{"cvss_score":9.8,"headline":"Weak cryptography in Modicon Premium, Modicon Quantum, Modicon M340, BMXNOR0200","id":"CVE-2018-7242","kev_date_added":null,"published":"2018-04-18"},{"cvss_score":9.8,"headline":"Auth bypass in Modicon M340, Modicon Premium, Modicon Quantum, BMXNOR0201","id":"CVE-2018-7760","kev_date_added":null,"published":"2018-04-18"},{"cvss_score":9.8,"headline":"Code injection in Modicon M340, Modicon Premium, Modicon Quantum, BMXNOR0202","id":"CVE-2018-7761","kev_date_added":null,"published":"2018-04-18"},{"cvss_score":8.8,"headline":"Command injection in Modicon Quantum","id":"CVE-2018-7240","kev_date_added":null,"published":"2018-04-18"},{"cvss_score":7.5,"headline":"Memory corruption in Modicon M340, Modicon Premium, Modicon Quantum, BMXNOR0200","id":"CVE-2018-7759","kev_date_added":null,"published":"2018-04-18"},{"cvss_score":7.5,"headline":"Memory corruption in Modicon M340, Modicon Premium, Modicon Quantum, BMXNOR0203","id":"CVE-2018-7762","kev_date_added":null,"published":"2018-04-18"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-05","vendors":["Schneider Electric SE"]},"summary":"Hardcoded accounts in Schneider Electric Modicon controllers allow attackers to gain unauthorized access and control over industrial systems.","url":"https://insights.sbomify.com/CVE-2018-7241/"}