{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2018-7296 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2018-7296 yet. Limit exposure of the affected software until one is available.","what":"CVE-2018-7296 is a medium-severity path traversal vulnerability in n/a, published on 22 Feb 2018. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2018-7296 and fix it if it is affected.\n\nWhat it is: CVE-2018-7296 is a medium-severity path traversal vulnerability in n/a, published on 22 Feb 2018. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2018-7296 in the wild and no public exploit code.\n\nAffected product: n/a. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2018-7296/ (Markdown: https://insights.sbomify.com/CVE-2018-7296/index.md)","id":"CVE-2018-7296","markdown":"https://insights.sbomify.com/CVE-2018-7296/index.md","name":"CVE-2018-7296","record":{"aliases":["GHSA-xhgp-9mrx-4vxr"],"analysis":{"component_type":"iot_embedded","fix_type":"upgrade","impacts":["data_read"],"network_reachable":"yes","non_default_config":false,"product_category":"Home automation controller","requires_auth":"none","summary":"Unauthenticated attackers can read the first line of arbitrary files on the Homematic CCU2 via a directory traversal vulnerability in the web interface.","user_interaction":"not_required","vuln_class":"path_traversal"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"mitre","cpe":[{"product":"homematic_central_control_unit_ccu2_firmware","vendor":"eq-3"}],"cvss":{"score":5.3,"severity":"medium","source":"nvd","vector":"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N","version":"3.0"},"cwes":[{"id":"CWE-22","name":"Improper Limitation of a Pathname to a Restricted Directory"}],"description":"Directory Traversal / Arbitrary File Read in User.getLanguage method in eQ-3 AG Homematic CCU2 2.29.2 and earlier allows remote attackers to read the first line of an arbitrary file on the CCU2's filesystem. This vulnerability can be exploited by unauthenticated attackers with access to the web interface.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Path traversal in n/a","id":"CVE-2018-7296","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"path_traversal","year":"2018"},"n_packages":0,"n_references":1,"next":{"headline":"Command injection in n/a","id":"CVE-2018-7297"},"packages":[],"prev":{"headline":"Other in n/a","id":"CVE-2018-7295"},"products":["n/a"],"published":"2018-02-22","related":[{"cvss_score":9.8,"headline":"Command injection in n/a","id":"CVE-2018-7297","kev_date_added":null,"published":"2018-02-22"},{"cvss_score":9.8,"headline":"Missing authorization in n/a","id":"CVE-2018-7301","kev_date_added":null,"published":"2018-02-22"},{"cvss_score":8.1,"headline":"Supply chain in n/a","id":"CVE-2018-7298","kev_date_added":null,"published":"2018-02-22"},{"cvss_score":8,"headline":"File upload in n/a","id":"CVE-2018-7299","kev_date_added":null,"published":"2018-02-22"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-05","vendors":["n/a"]},"summary":"Unauthenticated attackers can read the first line of arbitrary files on the Homematic CCU2 via a directory traversal vulnerability in the web interface.","url":"https://insights.sbomify.com/CVE-2018-7296/"}