{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2018-7300 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2018-7300 yet. Limit exposure of the affected software until one is available.","what":"CVE-2018-7300 is a critical path traversal vulnerability in n/a, published on 22 Feb 2018. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2018-7300 and fix it if it is affected.\n\nWhat it is: CVE-2018-7300 is a critical path traversal vulnerability in n/a, published on 22 Feb 2018. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2018-7300 in the wild and no public exploit code.\n\nAffected product: n/a. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2018-7300/ (Markdown: https://insights.sbomify.com/CVE-2018-7300/index.md)","id":"CVE-2018-7300","markdown":"https://insights.sbomify.com/CVE-2018-7300/index.md","name":"CVE-2018-7300","record":{"aliases":["GHSA-64v8-x795-vgp3"],"analysis":{"component_type":"iot_embedded","fix_type":"upgrade","impacts":["code_execution","data_modify"],"network_reachable":"yes","non_default_config":false,"product_category":"Homematic CCU2","requires_auth":"none","summary":"Unauthenticated attackers can exploit a directory traversal flaw to write arbitrary files and execute remote code on Homematic CCU2 devices.","user_interaction":"not_required","vuln_class":"path_traversal"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"mitre","cpe":[{"product":"homematic_ccu2_firmware","vendor":"eq-3"}],"cvss":{"score":9.8,"severity":"critical","source":"nvd","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"cwes":[{"id":"CWE-22","name":"Improper Limitation of a Pathname to a Restricted Directory"}],"description":"Directory Traversal / Arbitrary File Write / Remote Code Execution in the User.setLanguage method in eQ-3 AG Homematic CCU2 2.29.2 and earlier allows remote attackers to write arbitrary files to the device's filesystem. This vulnerability can be exploited by unauthenticated attackers with access to the web interface.","ecosystems":[],"exploits":{"exploitdb":1,"first_seen":"2018-03-30","github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[{"date":"2018-03-30","kind":"exploitdb","ref":"44361","stars":null,"title":"Homematic CCU2 2.29.23 - Arbitrary File Write"}],"tier":"poc_unverified"},"has_fix":null,"headline":"Path traversal in n/a","id":"CVE-2018-7300","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"path_traversal","year":"2018"},"n_packages":0,"n_references":2,"next":{"headline":"Missing authorization in n/a","id":"CVE-2018-7301"},"packages":[],"prev":{"headline":"File upload in n/a","id":"CVE-2018-7299"},"products":["n/a"],"published":"2018-02-22","related":[{"cvss_score":10,"headline":"Command injection in n/a","id":"CVE-2021-33032","kev_date_added":null,"published":"2021-07-22"},{"cvss_score":9.8,"headline":"Command injection in n/a","id":"CVE-2019-18937","kev_date_added":null,"published":"2019-11-14"},{"cvss_score":9.8,"headline":"Code injection in n/a","id":"CVE-2019-18938","kev_date_added":null,"published":"2019-11-14"},{"cvss_score":9.8,"headline":"Command injection in n/a","id":"CVE-2019-18939","kev_date_added":null,"published":"2019-11-14"},{"cvss_score":9.8,"headline":"Auth bypass in n/a","id":"CVE-2019-16199","kev_date_added":null,"published":"2019-09-17"},{"cvss_score":9.8,"headline":"Missing authorization in n/a","id":"CVE-2019-9584","kev_date_added":null,"published":"2019-08-14"},{"cvss_score":9.8,"headline":"Missing authorization in n/a","id":"CVE-2019-9585","kev_date_added":null,"published":"2019-08-14"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"},{"class":"attribution","licence":"GPL-2.0-or-later","name":"Exploit-DB"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-05","vendors":["n/a"]},"summary":"Unauthenticated attackers can exploit a directory traversal flaw to write arbitrary files and execute remote code on Homematic CCU2 devices.","url":"https://insights.sbomify.com/CVE-2018-7300/"}