{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2018-7778 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2018-7778 yet. Limit exposure of the affected software until one is available.","what":"CVE-2018-7778 is a critical authentication bypass vulnerability in Schneider Electric SE Evlink Charging Station, published on 3 Jul 2018. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2018-7778 and fix it if it is affected.\n\nWhat it is: CVE-2018-7778 is a critical authentication bypass vulnerability in Schneider Electric SE Evlink Charging Station, published on 3 Jul 2018. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2018-7778 in the wild and no public exploit code.\n\nAffected product: Schneider Electric SE Evlink Charging Station. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2018-7778/ (Markdown: https://insights.sbomify.com/CVE-2018-7778/index.md)","id":"CVE-2018-7778","markdown":"https://insights.sbomify.com/CVE-2018-7778/index.md","name":"CVE-2018-7778","record":{"aliases":["GHSA-vwm8-cpcx-vv4r"],"analysis":{"component_type":"iot_embedded","fix_type":"upgrade","impacts":["privilege_escalation","account_takeover"],"network_reachable":"yes","non_default_config":false,"product_category":"EV charging station","requires_auth":"none","summary":"Remote attackers can gain administrative privileges on Schneider Electric Evlink Charging Stations without authentication, requiring an upgrade to secure the device.","user_interaction":"not_required","vuln_class":"auth_bypass"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"schneider","cpe":[{"product":"evlink_charging_station_firmware","vendor":"schneider-electric"}],"cvss":{"score":9.8,"severity":"critical","source":"nvd","vector":"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","version":"3.0"},"cwes":[{"id":"CWE-306","name":"Missing Authentication for Critical Functionality"}],"description":"In Schneider Electric Evlink Charging Station versions prior to v3.2.0-12_v1, the Web Interface has an issue that may allow a remote attacker to gain administrative privileges without properly authenticating remote users.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Auth bypass in Evlink Charging Station","id":"CVE-2018-7778","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"auth_bypass","year":"2018"},"n_packages":0,"n_references":1,"next":{"headline":"Auth bypass in Wiser for KNX","id":"CVE-2018-7779"},"packages":[],"prev":{"headline":"Path traversal in U.Motion","id":"CVE-2018-7777"},"products":["Evlink Charging Station"],"published":"2018-07-03","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-09-17","vendors":["Schneider Electric SE"]},"summary":"Remote attackers can gain administrative privileges on Schneider Electric Evlink Charging Stations without authentication, requiring an upgrade to secure the device.","url":"https://insights.sbomify.com/CVE-2018-7778/"}