# CVE-2018-7797: Open redirect in Power Monitoring Expert, Energy Expert (formerly Power Manager) - EcoStruxure&#xaa; Power Monitoring Expert (PME) v8.2 (all editions), EcoStruxure&#xaa; Energy Expert 1.3 (formerly Power Manager), EcoStruxure&#xaa; Power SCADA Operation (PSO) 8.2 Advanced Reports and Dashboards Module, EcoStruxure&#xaa; Power Monitoring Expert (PME) v9.0, EcoStruxure&#xaa; Energy Expert v2.0, and EcoStruxure&#xaa;Power SCADA Operation (PSO) 9.0 Advanced Reports and Dashboards Module

> Attackers can redirect users to malicious sites via URL redirection in Schneider Electric Power Monitoring Expert and Energy Expert, facilitating phishing attacks.

- **Severity:** Medium 6.1 (`CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N`)
- **Exploited in the wild:** Not known
- **Login needed:** Not needed
- **Attackable:** Over the internet
- **Victim action needed:** A user has to click or open something
- **Fix available:** No
- **Published:** 17 Dec 2018
- **Updated:** 5 Aug 2024
- **Also known as:** GHSA-9p3j-xx7r-8mm9

## What is CVE-2018-7797?

CVE-2018-7797 is a medium-severity vulnerability in Schneider Electric SE Power Monitoring Expert, Energy Expert (formerly Power Manager) - EcoStruxure&#xaa; Power Monitoring Expert (PME) v8.2 (all editions), EcoStruxure&#xaa; Energy Expert 1.3 (formerly Power Manager), EcoStruxure&#xaa; Power SCADA Operation (PSO) 8.2 Advanced Reports and Dashboards Module, EcoStruxure&#xaa; Power Monitoring Expert (PME) v9.0, EcoStruxure&#xaa; Energy Expert v2.0, and EcoStruxure&#xaa;Power SCADA Operation (PSO) 9.0 Advanced Reports and Dashboards Module, published on 17 Dec 2018. An attacker can exploit it over the internet without logging in, and only if a user opens a file or follows a link.

### Official description

A URL redirection vulnerability exists in Power Monitoring Expert, Energy Expert (formerly Power Manager) - EcoStruxure Power Monitoring Expert (PME) v8.2 (all editions), EcoStruxure Energy Expert 1.3 (formerly Power Manager), EcoStruxure Power SCADA Operation (PSO) 8.2 Advanced Reports and Dashboards Module, EcoStruxure Power Monitoring Expert (PME) v9.0, EcoStruxure Energy Expert v2.0, and EcoStruxure Power SCADA Operation (PSO) 9.0 Advanced Reports and Dashboards Module which could cause a phishing attack when redirected to a malicious site.

Weakness: CWE-601 (URL Redirection to Untrusted Site)

## Which versions are affected by CVE-2018-7797?

It affects 3 products.


Products: Schneider-Electric Ecostruxure Energy Expert, Schneider-Electric Ecostruxure Power Monitoring Expert, Schneider-Electric Ecostruxure Power Scada Operation.

## How do I fix CVE-2018-7797?

No fix has been published for CVE-2018-7797 yet. Limit exposure of the affected software until one is available.

## Is CVE-2018-7797 being exploited?

There is no known exploitation of CVE-2018-7797 in the wild and no public exploit code.

## Other vulnerabilities in Schneider Electric SE Power Monitoring Expert, Energy Expert (formerly Power Manager) - EcoStruxure&#xaa; Power Monitoring Expert (PME) v8.2 (all editions), EcoStruxure&#xaa; Energy Expert 1.3 (formerly Power Manager), EcoStruxure&#xaa; Power SCADA Operation (PSO) 8.2 Advanced Reports and Dashboards Module, EcoStruxure&#xaa; Power Monitoring Expert (PME) v9.0, EcoStruxure&#xaa; Energy Expert v2.0, and EcoStruxure&#xaa;Power SCADA Operation (PSO) 9.0 Advanced Reports and Dashboards Module

- [CVE-2020-7547](https://insights.sbomify.com/CVE-2020-7547/): Privilege escalation in EcoStruxureª and SmartStruxureª Power Monitoring and SCADA Software (see security notification for version information) (high 8.8)
- [CVE-2020-7545](https://insights.sbomify.com/CVE-2020-7545/): Missing authorization in EcoStruxureª and SmartStruxureª Power Monitoring and SCADA Software (see security notification for version information) (high 7.2)
- [CVE-2020-7546](https://insights.sbomify.com/CVE-2020-7546/): Cross-site scripting in EcoStruxureª and SmartStruxureª Power Monitoring and SCADA Software (see security notification for version information) (medium 5.4)

## Fix prompt for AI coding agents

```text
Check this codebase for CVE-2018-7797 and fix it if it is affected.

What it is: CVE-2018-7797 is a medium-severity vulnerability in Schneider Electric SE Power Monitoring Expert, Energy Expert (formerly Power Manager) - EcoStruxure&#xaa; Power Monitoring Expert (PME) v8.2 (all editions), EcoStruxure&#xaa; Energy Expert 1.3 (formerly Power Manager), EcoStruxure&#xaa; Power SCADA Operation (PSO) 8.2 Advanced Reports and Dashboards Module, EcoStruxure&#xaa; Power Monitoring Expert (PME) v9.0, EcoStruxure&#xaa; Energy Expert v2.0, and EcoStruxure&#xaa;Power SCADA Operation (PSO) 9.0 Advanced Reports and Dashboards Module, published on 17 Dec 2018. An attacker can exploit it over the internet without logging in, and only if a user opens a file or follows a link.
Exploitation: There is no known exploitation of CVE-2018-7797 in the wild and no public exploit code.

Affected product: Schneider Electric SE Power Monitoring Expert, Energy Expert (formerly Power Manager) - EcoStruxure&#xaa; Power Monitoring Expert (PME) v8.2 (all editions), EcoStruxure&#xaa; Energy Expert 1.3 (formerly Power Manager), EcoStruxure&#xaa; Power SCADA Operation (PSO) 8.2 Advanced Reports and Dashboards Module, EcoStruxure&#xaa; Power Monitoring Expert (PME) v9.0, EcoStruxure&#xaa; Energy Expert v2.0, and EcoStruxure&#xaa;Power SCADA Operation (PSO) 9.0 Advanced Reports and Dashboards Module. No package-level version data is available, so check the vendor advisory linked from the reference page.

Task:
1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.
2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.
3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.
4. Run the tests and summarise what changed and why.
5. If nothing in the project is affected, say so and change nothing.

Reference: https://insights.sbomify.com/CVE-2018-7797/ (Markdown: https://insights.sbomify.com/CVE-2018-7797/index.md)
```

## Sources

- CVE record: https://www.cve.org/CVERecord?id=CVE-2018-7797
- NVD: https://nvd.nist.gov/vuln/detail/CVE-2018-7797
- OSV: https://osv.dev/vulnerability/CVE-2018-7797

---
From sbomify Insights: https://insights.sbomify.com/CVE-2018-7797/
Summaries are generated and may contain mistakes; the official description above is the record.