{"answers":{"affected":"It affects 59 products.","exploited":"There is no known exploitation of CVE-2018-7816 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2018-7816 yet. Limit exposure of the affected software until one is available.","what":"CVE-2018-7816 is a medium-severity missing authorization vulnerability in Pelco Sarix Enhanced and Spectra Enhanced, Pelco Sarix Enhanced 1st generation and Spectra Enhanced PTZ, published on 22 May 2019. Any signed-in user can exploit it over the network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2018-7816 and fix it if it is affected.\n\nWhat it is: CVE-2018-7816 is a medium-severity missing authorization vulnerability in Pelco Sarix Enhanced and Spectra Enhanced, Pelco Sarix Enhanced 1st generation and Spectra Enhanced PTZ, published on 22 May 2019. Any signed-in user can exploit it over the network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2018-7816 in the wild and no public exploit code.\n\nAffected product: Pelco Sarix Enhanced and Spectra Enhanced, Pelco Sarix Enhanced 1st generation and Spectra Enhanced PTZ. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2018-7816/ (Markdown: https://insights.sbomify.com/CVE-2018-7816/index.md)","id":"CVE-2018-7816","markdown":"https://insights.sbomify.com/CVE-2018-7816/index.md","name":"CVE-2018-7816","record":{"aliases":["GHSA-h89m-r85h-9g37"],"analysis":{"component_type":"iot_embedded","fix_type":"no_fix_stated","impacts":["data_modify"],"network_reachable":"yes","non_default_config":false,"product_category":"Pelco security camera","requires_auth":"low_privilege","summary":"A remote attacker can delete arbitrary files on Pelco Sarix Enhanced cameras due to missing authorization checks in the web GUI.","user_interaction":"not_required","vuln_class":"missing_authorization"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"schneider","cpe":[{"product":"d6220_firmware","vendor":"schneider-electric"},{"product":"d6220l_firmware","vendor":"schneider-electric"},{"product":"d6230_firmware","vendor":"schneider-electric"},{"product":"d6230l_firmware","vendor":"schneider-electric"},{"product":"ime119-1ei_firmware","vendor":"schneider-electric"},{"product":"ime119-1ep_firmware","vendor":"schneider-electric"},{"product":"ime119-1es_firmware","vendor":"schneider-electric"},{"product":"ime119-1i_firmware","vendor":"schneider-electric"},{"product":"ime119-1p_firmware","vendor":"schneider-electric"},{"product":"ime119-1s_firmware","vendor":"schneider-electric"},{"product":"ime119-1vi_firmware","vendor":"schneider-electric"},{"product":"ime119-1vp_firmware","vendor":"schneider-electric"},{"product":"ime119-1vs_firmware","vendor":"schneider-electric"},{"product":"ime219-1ei_firmware","vendor":"schneider-electric"},{"product":"ime219-1ep_firmware","vendor":"schneider-electric"},{"product":"ime219-1es_firmware","vendor":"schneider-electric"},{"product":"ime219-1i_firmware","vendor":"schneider-electric"},{"product":"ime219-1p_firmware","vendor":"schneider-electric"},{"product":"ime219-1s_firmware","vendor":"schneider-electric"},{"product":"ime219-1vi_firmware","vendor":"schneider-electric"},{"product":"ime219-1vp_firmware","vendor":"schneider-electric"},{"product":"ime219-1vs_firmware","vendor":"schneider-electric"},{"product":"ime3122-1ei_firmware","vendor":"schneider-electric"},{"product":"ime3122-1ep_firmware","vendor":"schneider-electric"},{"product":"ime3122-1es_firmware","vendor":"schneider-electric"},{"product":"ime3122-1i_firmware","vendor":"schneider-electric"},{"product":"ime3122-1p_firmware","vendor":"schneider-electric"},{"product":"ime3122-1s_firmware","vendor":"schneider-electric"},{"product":"ime3122-1vi_firmware","vendor":"schneider-electric"},{"product":"ime3122-1vp_firmware","vendor":"schneider-electric"},{"product":"ime3122-1vs_firmware","vendor":"schneider-electric"},{"product":"ime3122-b1i_firmware","vendor":"schneider-electric"},{"product":"ime3122-b1p_firmware","vendor":"schneider-electric"},{"product":"ime3122-b1s_firmware","vendor":"schneider-electric"},{"product":"ime319-1ei_firmware","vendor":"schneider-electric"},{"product":"ime319-1ep_firmware","vendor":"schneider-electric"},{"product":"ime319-1es_firmware","vendor":"schneider-electric"},{"product":"ime319-1i_firmware","vendor":"schneider-electric"},{"product":"ime319-1p_firmware","vendor":"schneider-electric"},{"product":"ime319-1s_firmware","vendor":"schneider-electric"},{"product":"ime319-1vi_firmware","vendor":"schneider-electric"},{"product":"ime319-1vp_firmware","vendor":"schneider-electric"},{"product":"ime319-1vs_firmware","vendor":"schneider-electric"},{"product":"ime319-b1i_firmware","vendor":"schneider-electric"},{"product":"ime319-b1p_firmware","vendor":"schneider-electric"},{"product":"ime319-b1s_firmware","vendor":"schneider-electric"},{"product":"imes19-1ei_firmware","vendor":"schneider-electric"},{"product":"imes19-1ep_firmware","vendor":"schneider-electric"},{"product":"imes19-1es_firmware","vendor":"schneider-electric"},{"product":"imes19-1i_firmware","vendor":"schneider-electric"},{"product":"imes19-1p_firmware","vendor":"schneider-electric"},{"product":"imes19-1s_firmware","vendor":"schneider-electric"},{"product":"imes19-1vi_firmware","vendor":"schneider-electric"},{"product":"imes19-1vp_firmware","vendor":"schneider-electric"},{"product":"imes19-1vs_firmware","vendor":"schneider-electric"},{"product":"ixe11_firmware","vendor":"schneider-electric"},{"product":"ixe21_firmware","vendor":"schneider-electric"},{"product":"ixe31_firmware","vendor":"schneider-electric"},{"product":"ixes1_firmware","vendor":"schneider-electric"}],"cvss":{"score":6.5,"severity":"medium","source":"nvd","vector":"CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:N","version":"3.0"},"cwes":[],"description":"A Permissions, Privileges, and Access Control vulnerability exists in the web-based GUI of the 1st Gen Pelco Sarix Enhanced Camera that could allow a remote attacker to delete an arbitrary file.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Missing authorization in Pelco Sarix Enhanced and Spectra Enhanced, Pelco Sarix Enhanced 1st generation and Spectra Enhanced PTZ","id":"CVE-2018-7816","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"missing_authorization","year":"2018"},"n_packages":0,"n_references":1,"next":{"headline":"Use after free in Zelio Soft 2 v5.1 and prior versions","id":"CVE-2018-7817"},"packages":[],"prev":{"headline":"Memory corruption in Eurotherm by Schneider Electric GUIcon V2.0 (Gold Build 683.0)","id":"CVE-2018-7815"},"products":["Pelco Sarix Enhanced and Spectra Enhanced, Pelco Sarix Enhanced 1st generation and Spectra Enhanced PTZ"],"published":"2019-05-22","related":[{"cvss_score":8.8,"headline":"Command injection in Pelco Sarix Enhanced and Spectra Enhanced, Pelco Sarix Enhanced 1st generation and Spectra Enhanced PTZ","id":"CVE-2018-7825","kev_date_added":null,"published":"2019-05-22"},{"cvss_score":8.8,"headline":"Command injection in Pelco Sarix Enhanced and Spectra Enhanced, Pelco Sarix Enhanced 1st generation and Spectra Enhanced PTZ","id":"CVE-2018-7826","kev_date_added":null,"published":"2019-05-22"},{"cvss_score":8.8,"headline":"Cross-site request forgery in Pelco Sarix Enhanced and Spectra Enhanced, Pelco Sarix Enhanced 1st generation and Spectra Enhanced PTZ","id":"CVE-2018-7828","kev_date_added":null,"published":"2019-05-22"},{"cvss_score":8.8,"headline":"Command injection in Pelco Sarix Enhanced and Spectra Enhanced, Pelco Sarix Enhanced 1st generation and Spectra Enhanced PTZ","id":"CVE-2018-7829","kev_date_added":null,"published":"2019-05-22"},{"cvss_score":5.4,"headline":"Cross-site scripting in Pelco Sarix Enhanced and Spectra Enhanced, Pelco Sarix Enhanced 1st generation and Spectra Enhanced PTZ","id":"CVE-2018-7827","kev_date_added":null,"published":"2019-05-22"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-05","vendors":["Pelco"]},"summary":"A remote attacker can delete arbitrary files on Pelco Sarix Enhanced cameras due to missing authorization checks in the web GUI.","url":"https://insights.sbomify.com/CVE-2018-7816/"}