{"answers":{"affected":"It affects 4 products.","exploited":"There is no known exploitation of CVE-2018-7820 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2018-7820 yet. Limit exposure of the affected software until one is available.","what":"CVE-2018-7820 is a critical vulnerability in Schneider Electric SE APC UPS Network Management Card 2 AOS, published on 17 Sep 2019. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2018-7820 and fix it if it is affected.\n\nWhat it is: CVE-2018-7820 is a critical vulnerability in Schneider Electric SE APC UPS Network Management Card 2 AOS, published on 17 Sep 2019. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2018-7820 in the wild and no public exploit code.\n\nAffected product: Schneider Electric SE APC UPS Network Management Card 2 AOS. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2018-7820/ (Markdown: https://insights.sbomify.com/CVE-2018-7820/index.md)","id":"CVE-2018-7820","markdown":"https://insights.sbomify.com/CVE-2018-7820/index.md","name":"CVE-2018-7820","record":{"aliases":["GHSA-ff72-jpjq-gxxc"],"analysis":{"component_type":"network_device","fix_type":"upgrade","impacts":["data_read"],"network_reachable":"yes","non_default_config":true,"product_category":"UPS Network Management Card","requires_auth":"none","summary":"Attackers can view remote monitoring credentials in plaintext if the feature is enabled then disabled, exposing sensitive access data.","user_interaction":"not_required","vuln_class":"information_disclosure"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"schneider","cpe":[{"product":"ap9630_firmware","vendor":"schneider-electric"},{"product":"ap9631_firmware","vendor":"schneider-electric"},{"product":"ap9635_firmware","vendor":"schneider-electric"},{"product":"smart-ups_srt_5kva_firmware","vendor":"schneider-electric"}],"cvss":{"score":9.8,"severity":"critical","source":"nvd","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"cwes":[{"id":"CWE-522","name":"Insufficiently Protected Credentials"},{"id":"CWE-255","name":null}],"description":"A Credentials Management CWE-255 vulnerability exists in the APC UPS Network Management Card 2 AOS v6.5.6, which could cause Remote Monitoring Credentials to be viewed in plaintext when Remote Monitoring is enabled, and then disabled.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Information disclosure in APC UPS Network Management Card 2 AOS","id":"CVE-2018-7820","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"information_disclosure","year":"2018"},"n_packages":0,"n_references":1,"next":{"headline":"Denial of service in SoMachine Basic and Modicon M221, SoMachine Basic, all versions Modicon M221, all references, all versions prior to firmware V1.10.0.0","id":"CVE-2018-7821"},"packages":[],"prev":{"headline":"Use after free in Zelio Soft 2 v5.1 and prior versions","id":"CVE-2018-7817"},"products":["APC UPS Network Management Card 2 AOS"],"published":"2019-09-17","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-05","vendors":["Schneider Electric SE"]},"summary":"Attackers can view remote monitoring credentials in plaintext if the feature is enabled then disabled, exposing sensitive access data.","url":"https://insights.sbomify.com/CVE-2018-7820/"}