{"answers":{"affected":"It affects 59 products.","exploited":"There is no known exploitation of CVE-2018-7829 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2018-7829 yet. Limit exposure of the affected software until one is available.","what":"CVE-2018-7829 is a high-severity command injection vulnerability in Pelco Sarix Enhanced and Spectra Enhanced, Pelco Sarix Enhanced 1st generation and Spectra Enhanced PTZ, published on 22 May 2019. Any signed-in user can exploit it over the network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2018-7829 and fix it if it is affected.\n\nWhat it is: CVE-2018-7829 is a high-severity command injection vulnerability in Pelco Sarix Enhanced and Spectra Enhanced, Pelco Sarix Enhanced 1st generation and Spectra Enhanced PTZ, published on 22 May 2019. Any signed-in user can exploit it over the network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2018-7829 in the wild and no public exploit code.\n\nAffected product: Pelco Sarix Enhanced and Spectra Enhanced, Pelco Sarix Enhanced 1st generation and Spectra Enhanced PTZ. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2018-7829/ (Markdown: https://insights.sbomify.com/CVE-2018-7829/index.md)","id":"CVE-2018-7829","markdown":"https://insights.sbomify.com/CVE-2018-7829/index.md","name":"CVE-2018-7829","record":{"aliases":["GHSA-37cj-hcx2-8pv7"],"analysis":{"component_type":"iot_embedded","fix_type":"no_fix_stated","impacts":["code_execution"],"network_reachable":"yes","non_default_config":false,"product_category":"Pelco security camera","requires_auth":"low_privilege","summary":"Attackers can execute arbitrary system commands on Pelco Sarix and Spectra Enhanced cameras due to improper neutralization of special elements in queries.","user_interaction":"not_required","vuln_class":"command_injection"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"schneider","cpe":[{"product":"d6220_firmware","vendor":"schneider-electric"},{"product":"d6220l_firmware","vendor":"schneider-electric"},{"product":"d6230_firmware","vendor":"schneider-electric"},{"product":"d6230l_firmware","vendor":"schneider-electric"},{"product":"ime119-1ei_firmware","vendor":"schneider-electric"},{"product":"ime119-1ep_firmware","vendor":"schneider-electric"},{"product":"ime119-1es_firmware","vendor":"schneider-electric"},{"product":"ime119-1i_firmware","vendor":"schneider-electric"},{"product":"ime119-1p_firmware","vendor":"schneider-electric"},{"product":"ime119-1s_firmware","vendor":"schneider-electric"},{"product":"ime119-1vi_firmware","vendor":"schneider-electric"},{"product":"ime119-1vp_firmware","vendor":"schneider-electric"},{"product":"ime119-1vs_firmware","vendor":"schneider-electric"},{"product":"ime219-1ei_firmware","vendor":"schneider-electric"},{"product":"ime219-1ep_firmware","vendor":"schneider-electric"},{"product":"ime219-1es_firmware","vendor":"schneider-electric"},{"product":"ime219-1i_firmware","vendor":"schneider-electric"},{"product":"ime219-1p_firmware","vendor":"schneider-electric"},{"product":"ime219-1s_firmware","vendor":"schneider-electric"},{"product":"ime219-1vi_firmware","vendor":"schneider-electric"},{"product":"ime219-1vp_firmware","vendor":"schneider-electric"},{"product":"ime219-1vs_firmware","vendor":"schneider-electric"},{"product":"ime3122-1ei_firmware","vendor":"schneider-electric"},{"product":"ime3122-1ep_firmware","vendor":"schneider-electric"},{"product":"ime3122-1es_firmware","vendor":"schneider-electric"},{"product":"ime3122-1i_firmware","vendor":"schneider-electric"},{"product":"ime3122-1p_firmware","vendor":"schneider-electric"},{"product":"ime3122-1s_firmware","vendor":"schneider-electric"},{"product":"ime3122-1vi_firmware","vendor":"schneider-electric"},{"product":"ime3122-1vp_firmware","vendor":"schneider-electric"},{"product":"ime3122-1vs_firmware","vendor":"schneider-electric"},{"product":"ime3122-b1i_firmware","vendor":"schneider-electric"},{"product":"ime3122-b1p_firmware","vendor":"schneider-electric"},{"product":"ime3122-b1s_firmware","vendor":"schneider-electric"},{"product":"ime319-1ei_firmware","vendor":"schneider-electric"},{"product":"ime319-1ep_firmware","vendor":"schneider-electric"},{"product":"ime319-1es_firmware","vendor":"schneider-electric"},{"product":"ime319-1i_firmware","vendor":"schneider-electric"},{"product":"ime319-1p_firmware","vendor":"schneider-electric"},{"product":"ime319-1s_firmware","vendor":"schneider-electric"},{"product":"ime319-1vi_firmware","vendor":"schneider-electric"},{"product":"ime319-1vp_firmware","vendor":"schneider-electric"},{"product":"ime319-1vs_firmware","vendor":"schneider-electric"},{"product":"ime319-b1i_firmware","vendor":"schneider-electric"},{"product":"ime319-b1p_firmware","vendor":"schneider-electric"},{"product":"ime319-b1s_firmware","vendor":"schneider-electric"},{"product":"imes19-1ei_firmware","vendor":"schneider-electric"},{"product":"imes19-1ep_firmware","vendor":"schneider-electric"},{"product":"imes19-1es_firmware","vendor":"schneider-electric"},{"product":"imes19-1i_firmware","vendor":"schneider-electric"},{"product":"imes19-1p_firmware","vendor":"schneider-electric"},{"product":"imes19-1s_firmware","vendor":"schneider-electric"},{"product":"imes19-1vi_firmware","vendor":"schneider-electric"},{"product":"imes19-1vp_firmware","vendor":"schneider-electric"},{"product":"imes19-1vs_firmware","vendor":"schneider-electric"},{"product":"ixe11_firmware","vendor":"schneider-electric"},{"product":"ixe21_firmware","vendor":"schneider-electric"},{"product":"ixe31_firmware","vendor":"schneider-electric"},{"product":"ixes1_firmware","vendor":"schneider-electric"}],"cvss":{"score":8.8,"severity":"high","source":"nvd","vector":"CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","version":"3.0"},"cwes":[{"id":"CWE-943","name":"Improper Neutralization of Special Elements in Data Query Logic"}],"description":"An Improper Neutralization of Special Elements in Query vulnerability exists in the 1st Gen. Pelco Sarix Enhanced Camera and Spectra Enhanced PTZ Camera which allows an attacker to execute arbitrary system commands.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Command injection in Pelco Sarix Enhanced and Spectra Enhanced, Pelco Sarix Enhanced 1st generation and Spectra Enhanced PTZ","id":"CVE-2018-7829","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"command_injection","year":"2018"},"n_packages":0,"n_references":1,"next":{"headline":"Other in Embedded Web Servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200","id":"CVE-2018-7830"},"packages":[],"prev":{"headline":"Cross-site request forgery in Pelco Sarix Enhanced and Spectra Enhanced, Pelco Sarix Enhanced 1st generation and Spectra Enhanced PTZ","id":"CVE-2018-7828"},"products":["Pelco Sarix Enhanced and Spectra Enhanced, Pelco Sarix Enhanced 1st generation and Spectra Enhanced PTZ"],"published":"2019-05-22","related":[{"cvss_score":8.8,"headline":"Command injection in Pelco Sarix Enhanced and Spectra Enhanced, Pelco Sarix Enhanced 1st generation and Spectra Enhanced PTZ","id":"CVE-2018-7825","kev_date_added":null,"published":"2019-05-22"},{"cvss_score":8.8,"headline":"Command injection in Pelco Sarix Enhanced and Spectra Enhanced, Pelco Sarix Enhanced 1st generation and Spectra Enhanced PTZ","id":"CVE-2018-7826","kev_date_added":null,"published":"2019-05-22"},{"cvss_score":8.8,"headline":"Cross-site request forgery in Pelco Sarix Enhanced and Spectra Enhanced, Pelco Sarix Enhanced 1st generation and Spectra Enhanced PTZ","id":"CVE-2018-7828","kev_date_added":null,"published":"2019-05-22"},{"cvss_score":6.5,"headline":"Missing authorization in Pelco Sarix Enhanced and Spectra Enhanced, Pelco Sarix Enhanced 1st generation and Spectra Enhanced PTZ","id":"CVE-2018-7816","kev_date_added":null,"published":"2019-05-22"},{"cvss_score":5.4,"headline":"Cross-site scripting in Pelco Sarix Enhanced and Spectra Enhanced, Pelco Sarix Enhanced 1st generation and Spectra Enhanced PTZ","id":"CVE-2018-7827","kev_date_added":null,"published":"2019-05-22"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-05","vendors":["n/a"]},"summary":"Attackers can execute arbitrary system commands on Pelco Sarix and Spectra Enhanced cameras due to improper neutralization of special elements in queries.","url":"https://insights.sbomify.com/CVE-2018-7829/"}