{"answers":{"affected":"It affects 4 products.","exploited":"There is no known exploitation of CVE-2018-7830 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2018-7830 yet. Limit exposure of the affected software until one is available.","what":"CVE-2018-7830 is a high-severity vulnerability in Schneider Electric SE Embedded Web Servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200, published on 30 Nov 2018. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2018-7830 and fix it if it is affected.\n\nWhat it is: CVE-2018-7830 is a high-severity vulnerability in Schneider Electric SE Embedded Web Servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200, published on 30 Nov 2018. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2018-7830 in the wild and no public exploit code.\n\nAffected product: Schneider Electric SE Embedded Web Servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2018-7830/ (Markdown: https://insights.sbomify.com/CVE-2018-7830/index.md)","id":"CVE-2018-7830","markdown":"https://insights.sbomify.com/CVE-2018-7830/index.md","name":"CVE-2018-7830","record":{"aliases":["GHSA-334h-jmqc-fx27"],"analysis":{"component_type":"ics_ot","fix_type":"patch","impacts":["denial_of_service"],"network_reachable":"yes","non_default_config":false,"product_category":"Modicon PLC web server","requires_auth":"none","summary":"Attackers can cause a brief denial of service on Schneider Electric Modicon PLCs by sending crafted HTTP requests to the embedded web server.","user_interaction":"not_required","vuln_class":"other"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"schneider","cpe":[{"product":"modicom_bmxnor0200h_firmware","vendor":"schneider-electric"},{"product":"modicom_m340_firmware","vendor":"schneider-electric"},{"product":"modicom_premium_firmware","vendor":"schneider-electric"},{"product":"modicom_quantum_firmware","vendor":"schneider-electric"}],"cvss":{"score":7.5,"severity":"high","source":"nvd","vector":"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","version":"3.0"},"cwes":[{"id":"CWE-113","name":"Improper Neutralization of CRLF Sequences in HTTP Headers"}],"description":"Improper Neutralization of CRLF Sequences in HTTP Headers ('HTTP Response Splitting') vulnerability exists in the embedded web servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200 where a denial of service can occur for ~1 minute by sending a specially crafted HTTP request.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Other in Embedded Web Servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200","id":"CVE-2018-7830","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"other","year":"2018"},"n_packages":0,"n_references":2,"next":{"headline":"Cross-site scripting in Embedded Web Servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200","id":"CVE-2018-7831"},"packages":[],"prev":{"headline":"Command injection in Pelco Sarix Enhanced and Spectra Enhanced, Pelco Sarix Enhanced 1st generation and Spectra Enhanced PTZ","id":"CVE-2018-7829"},"products":["Embedded Web Servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200"],"published":"2018-11-30","related":[{"cvss_score":9.8,"headline":"Auth bypass in Embedded Web Servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200","id":"CVE-2018-7809","kev_date_added":null,"published":"2018-11-30"},{"cvss_score":9.8,"headline":"Auth bypass in Embedded Web Servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200","id":"CVE-2018-7811","kev_date_added":null,"published":"2018-11-30"},{"cvss_score":8.8,"headline":"Cross-site scripting in Embedded Web Servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200","id":"CVE-2018-7831","kev_date_added":null,"published":"2018-11-30"},{"cvss_score":7.5,"headline":"Information disclosure in Embedded Web Servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200","id":"CVE-2018-7812","kev_date_added":null,"published":"2018-12-17"},{"cvss_score":7.5,"headline":"Denial of service in Embedded Web Servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200","id":"CVE-2018-7833","kev_date_added":null,"published":"2018-12-17"},{"cvss_score":6.1,"headline":"Open redirect in Embedded Web Servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200","id":"CVE-2018-7804","kev_date_added":null,"published":"2018-12-17"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-05","vendors":["Schneider Electric SE"]},"summary":"Attackers can cause a brief denial of service on Schneider Electric Modicon PLCs by sending crafted HTTP requests to the embedded web server.","url":"https://insights.sbomify.com/CVE-2018-7830/"}