{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2018-7832 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2018-7832 yet. Limit exposure of the affected software until one is available.","what":"CVE-2018-7832 is a high-severity code injection vulnerability in Schneider Electric SE Pro-Face GP-Pro EX v4.08 and previous versions, published on 24 Dec 2018. Any signed-in user can exploit it over the network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2018-7832 and fix it if it is affected.\n\nWhat it is: CVE-2018-7832 is a high-severity code injection vulnerability in Schneider Electric SE Pro-Face GP-Pro EX v4.08 and previous versions, published on 24 Dec 2018. Any signed-in user can exploit it over the network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2018-7832 in the wild and no public exploit code.\n\nAffected product: Schneider Electric SE Pro-Face GP-Pro EX v4.08 and previous versions. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2018-7832/ (Markdown: https://insights.sbomify.com/CVE-2018-7832/index.md)","id":"CVE-2018-7832","markdown":"https://insights.sbomify.com/CVE-2018-7832/index.md","name":"CVE-2018-7832","record":{"aliases":["GHSA-fhmf-2c4w-wccg"],"analysis":{"component_type":"desktop_application","fix_type":"upgrade","impacts":["code_execution"],"network_reachable":"yes","non_default_config":false,"product_category":"HMI configuration software","requires_auth":"low_privilege","summary":"Improper input validation in Pro-Face GP-Pro EX allows arbitrary code execution when the application is launched.","user_interaction":"not_required","vuln_class":"code_injection"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"schneider","cpe":[{"product":"pro-face_gp-pro_ex","vendor":"schneider-electric"}],"cvss":{"score":8.8,"severity":"high","source":"nvd","vector":"CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","version":"3.0"},"cwes":[{"id":"CWE-20","name":"Improper Input Validation"}],"description":"An Improper Input Validation vulnerability exists in Pro-Face GP-Pro EX v4.08 and previous versions which could cause the execution arbitrary executable when GP-Pro EX is launched.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Code injection in Pro-Face GP-Pro EX v4.08 and previous versions","id":"CVE-2018-7832","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"code_injection","year":"2018"},"n_packages":0,"n_references":3,"next":{"headline":"Denial of service in Embedded Web Servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200","id":"CVE-2018-7833"},"packages":[],"prev":{"headline":"Cross-site scripting in Embedded Web Servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200","id":"CVE-2018-7831"},"products":["Pro-Face GP-Pro EX v4.08 and previous versions"],"published":"2018-12-24","related":[{"cvss_score":5.3,"headline":"Memory corruption in GP-Pro EX WinGP for PC/AT","id":"CVE-2023-3953","kev_date_added":null,"published":"2023-08-09"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-05","vendors":["Schneider Electric SE"]},"summary":"Improper input validation in Pro-Face GP-Pro EX allows arbitrary code execution when the application is launched.","url":"https://insights.sbomify.com/CVE-2018-7832/"}