{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2018-7834 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2018-7834 yet. Limit exposure of the affected software until one is available.","what":"CVE-2018-7834 is a medium-severity cross-site scripting vulnerability in ConneXium Gateway, TSXETG100 - all versions, published on 22 May 2019. An attacker can exploit it over the internet without logging in, and only if a user opens a file or follows a link."},"fix_prompt":"Check this codebase for CVE-2018-7834 and fix it if it is affected.\n\nWhat it is: CVE-2018-7834 is a medium-severity cross-site scripting vulnerability in ConneXium Gateway, TSXETG100 - all versions, published on 22 May 2019. An attacker can exploit it over the internet without logging in, and only if a user opens a file or follows a link.\nExploitation: There is no known exploitation of CVE-2018-7834 in the wild and no public exploit code.\n\nAffected product: ConneXium Gateway, TSXETG100 - all versions. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2018-7834/ (Markdown: https://insights.sbomify.com/CVE-2018-7834/index.md)","id":"CVE-2018-7834","markdown":"https://insights.sbomify.com/CVE-2018-7834/index.md","name":"CVE-2018-7834","record":{"aliases":["GHSA-7577-w49p-2f79"],"analysis":{"component_type":"network_device","fix_type":"no_fix_stated","impacts":["code_execution"],"network_reachable":"yes","non_default_config":false,"product_category":"ConneXium Gateway","requires_auth":"none","summary":"An attacker can execute arbitrary scripts in a user's browser via a crafted URL in the ConneXium Gateway TSXETG100.","user_interaction":"required","vuln_class":"xss"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"schneider","cpe":[{"product":"tsxetg100_firmware","vendor":"schneider-electric"}],"cvss":{"score":6.1,"severity":"medium","source":"nvd","vector":"CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N","version":"3.0"},"cwes":[{"id":"CWE-79","name":"Improper Neutralization of Input During Web Page Generation"}],"description":"A CWE-79 Cross-Site Scripting vulnerability exists in all versions of the TSXETG100 allowing an attacker to send a specially crafted URL with an embedded script to a user that would then be executed within the context of that user.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Cross-site scripting in ConneXium Gateway, TSXETG100 - all versions","id":"CVE-2018-7834","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"xss","year":"2018"},"n_packages":0,"n_references":1,"next":{"headline":"Path traversal in IIoT Monitor 3.1.38","id":"CVE-2018-7835"},"packages":[],"prev":{"headline":"Denial of service in Embedded Web Servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200","id":"CVE-2018-7833"},"products":["ConneXium Gateway, TSXETG100 - all versions"],"published":"2019-05-22","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-05","vendors":["n/a"]},"summary":"An attacker can execute arbitrary scripts in a user's browser via a crafted URL in the ConneXium Gateway TSXETG100.","url":"https://insights.sbomify.com/CVE-2018-7834/"}