{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2018-7836 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2018-7836 yet. Limit exposure of the affected software until one is available.","what":"CVE-2018-7836 is a critical vulnerability in Schneider Electric SE IIoT Monitor 3.1.38, published on 24 Dec 2018. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2018-7836 and fix it if it is affected.\n\nWhat it is: CVE-2018-7836 is a critical vulnerability in Schneider Electric SE IIoT Monitor 3.1.38, published on 24 Dec 2018. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2018-7836 in the wild and no public exploit code.\n\nAffected product: Schneider Electric SE IIoT Monitor 3.1.38. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2018-7836/ (Markdown: https://insights.sbomify.com/CVE-2018-7836/index.md)","id":"CVE-2018-7836","markdown":"https://insights.sbomify.com/CVE-2018-7836/index.md","name":"CVE-2018-7836","record":{"aliases":["GHSA-5r23-4mrh-r3pm"],"analysis":{"component_type":"ics_ot","fix_type":"patch","impacts":["code_execution"],"network_reachable":"yes","non_default_config":false,"product_category":"IIoT Monitor","requires_auth":"none","summary":"Attackers can upload and execute malicious files in Schneider Electric IIoT Monitor, leading to remote code execution.","user_interaction":"not_required","vuln_class":"file_upload"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"schneider","cpe":[{"product":"iiot_monitor","vendor":"schneider-electric"}],"cvss":{"score":9.8,"severity":"critical","source":"nvd","vector":"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","version":"3.0"},"cwes":[{"id":"CWE-434","name":"Unrestricted Upload of File with Dangerous Type"}],"description":"An unrestricted Upload of File with Dangerous Type vulnerability exists on numerous methods of the IIoT Monitor 3.1.38 software that could allow upload and execution of malicious files.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"File upload in IIoT Monitor 3.1.38","id":"CVE-2018-7836","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"file_upload","year":"2018"},"n_packages":0,"n_references":2,"next":{"headline":"XML external entity in IIoT Monitor 3.1.38","id":"CVE-2018-7837"},"packages":[],"prev":{"headline":"Path traversal in IIoT Monitor 3.1.38","id":"CVE-2018-7835"},"products":["IIoT Monitor 3.1.38"],"published":"2018-12-24","related":[{"cvss_score":5.5,"headline":"Weak cryptography in IIoT Monitor 3.1.38","id":"CVE-2018-7839","kev_date_added":null,"published":"2019-02-06"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-05","vendors":["Schneider Electric SE"]},"summary":"Attackers can upload and execute malicious files in Schneider Electric IIoT Monitor, leading to remote code execution.","url":"https://insights.sbomify.com/CVE-2018-7836/"}