{"answers":{"affected":"It affects 2 products.","exploited":"There is no known exploitation of CVE-2018-8868 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2018-8868 yet. Limit exposure of the affected software until one is available.","what":"CVE-2018-8868 is a medium-severity vulnerability in Medtronic 24950 MyCareLink Monitor, published on 2 Jul 2018. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2018-8868 and fix it if it is affected.\n\nWhat it is: CVE-2018-8868 is a medium-severity vulnerability in Medtronic 24950 MyCareLink Monitor, published on 2 Jul 2018. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2018-8868 in the wild and no public exploit code.\n\nAffected product: Medtronic 24950 MyCareLink Monitor. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2018-8868/ (Markdown: https://insights.sbomify.com/CVE-2018-8868/index.md)","id":"CVE-2018-8868","markdown":"https://insights.sbomify.com/CVE-2018-8868/index.md","name":"CVE-2018-8868","record":{"aliases":["GHSA-c9h8-j583-w6wh"],"analysis":{"component_type":"iot_embedded","fix_type":"patch","impacts":["data_read","data_modify"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Medical device monitor","requires_auth":"low_privilege","summary":"Attackers with physical proximity can exploit exposed debug code to read and write arbitrary memory on implantable cardiac devices via wireless protocols.","user_interaction":"not_required","vuln_class":"security_feature_bypass"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[{"product":"24950_mycarelink_monitor_firmware","vendor":"medtronic"},{"product":"24952_mycarelink_monitor_firmware","vendor":"medtronic"}],"cvss":{"score":6.2,"severity":"medium","source":"cna","vector":"CVSS:3.1/AV:P/AC:H/PR:L/UI:N/S:C/C:H/I:L/A:L","version":"3.1"},"cwes":[{"id":"CWE-749","name":"Exposed Dangerous Method or Function"}],"description":"Medtronic 24950 MyCareLink Monitor and 24952 MyCareLink Monitor contains debug code meant to test the functionality of the monitor's communication interfaces, including the interface between the monitor and implantable cardiac device. An attacker with physical access to the device can exploit other vulnerabilities to access this debug functionality. This debug functionality provides the ability to read and write arbitrary memory values to implantable cardiac devices via inductive or short range wireless protocols. An attacker with close physical proximity to a target implantable cardiac device can use this debug functionality.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Medtronic MyCareLink Patient Monitor Exposed Dangerous Method or Function","id":"CVE-2018-8868","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"security_feature_bypass","year":"2018"},"n_packages":0,"n_references":2,"next":{"headline":"Other in IDS 2102","id":"CVE-2018-8869"},"packages":[],"prev":{"headline":"Denial of service in GE PACSystems RX3i CPE305/310 version 9.20 and prior RX3i CPE330 version 9.21 and prior RX3i CPE 400 version 9.30 and prior PACSystems RSTi-EP CPE 100 all versionsPACSystems CPU320/CRU320 RXi all versions","id":"CVE-2018-8867"},"products":["24950 MyCareLink Monitor","24952 MyCareLink Monitor"],"published":"2018-07-02","related":[{"cvss_score":6.4,"headline":"Medtronic MyCareLink Patient Monitor Use of Hard-coded Password","id":"CVE-2018-8870","kev_date_added":null,"published":"2018-07-02"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2025-05-22","vendors":["Medtronic"]},"summary":"Attackers with physical proximity can exploit exposed debug code to read and write arbitrary memory on implantable cardiac devices via wireless protocols.","url":"https://insights.sbomify.com/CVE-2018-8868/"}