{"answers":{"affected":"It affects 2 products.","exploited":"There is no known exploitation of CVE-2019-10120 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2019-10120 yet. Limit exposure of the affected software until one is available.","what":"CVE-2019-10120 is a high-severity authentication bypass vulnerability in n/a, published on 10 Jul 2019. Any signed-in user can exploit it over the network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2019-10120 and fix it if it is affected.\n\nWhat it is: CVE-2019-10120 is a high-severity authentication bypass vulnerability in n/a, published on 10 Jul 2019. Any signed-in user can exploit it over the network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2019-10120 in the wild and no public exploit code.\n\nAffected product: n/a. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2019-10120/ (Markdown: https://insights.sbomify.com/CVE-2019-10120/index.md)","id":"CVE-2019-10120","markdown":"https://insights.sbomify.com/CVE-2019-10120/index.md","name":"CVE-2019-10120","record":{"aliases":["GHSA-qp96-5rrf-qmcp"],"analysis":{"component_type":"iot_embedded","fix_type":"upgrade","impacts":["account_takeover"],"network_reachable":"yes","non_default_config":false,"product_category":"HomeMatic CCU","requires_auth":"low_privilege","summary":"Attackers can maintain unauthorized access by reusing session IDs after logout on HomeMatic CCU devices, leading to account takeover.","user_interaction":"not_required","vuln_class":"auth_bypass"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"mitre","cpe":[{"product":"ccu2_firmware","vendor":"eq-3"},{"product":"ccu3_firmware","vendor":"eq-3"}],"cvss":{"score":8.8,"severity":"high","source":"nvd","vector":"CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","version":"3.0"},"cwes":[{"id":"CWE-384","name":"Session Fixation"}],"description":"On eQ-3 HomeMatic CCU2 devices before 2.41.8 and CCU3 devices before 3.43.16, automatic login configuration (aka setAutoLogin) can be achieved by continuing to use a session ID after a logout, aka HMCCU-154.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Auth bypass in n/a","id":"CVE-2019-10120","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"auth_bypass","year":"2019"},"n_packages":0,"n_references":2,"next":{"headline":"Missing authorization in n/a","id":"CVE-2019-10121"},"packages":[],"prev":{"headline":"Auth bypass in n/a","id":"CVE-2019-10119"},"products":["n/a"],"published":"2019-07-10","related":[{"cvss_score":9.8,"headline":"Auth bypass in n/a","id":"CVE-2019-10119","kev_date_added":null,"published":"2019-07-10"},{"cvss_score":9.8,"headline":"Missing authorization in n/a","id":"CVE-2019-10121","kev_date_added":null,"published":"2019-07-10"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2019-10122","kev_date_added":null,"published":"2019-07-10"},{"cvss_score":8.8,"headline":"Command injection in n/a","id":"CVE-2019-14423","kev_date_added":null,"published":"2019-10-17"},{"cvss_score":8.8,"headline":"Missing authorization in n/a","id":"CVE-2019-14473","kev_date_added":null,"published":"2019-08-06"},{"cvss_score":7.5,"headline":"Missing authorization in n/a","id":"CVE-2019-14475","kev_date_added":null,"published":"2019-08-05"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-04","vendors":["n/a"]},"summary":"Attackers can maintain unauthorized access by reusing session IDs after logout on HomeMatic CCU devices, leading to account takeover.","url":"https://insights.sbomify.com/CVE-2019-10120/"}