{"answers":{"affected":"2 open source packages ship an affected version, including org.jenkins-ci.plugins:electricflow. It affects 1 product.","exploited":"There is no known exploitation of CVE-2019-10331 in the wild and no public exploit code.","fix":"Upgrade org.jenkins-ci.plugins:electricflow to 1.1.7 or later.","what":"CVE-2019-10331 is a medium-severity vulnerability in Jenkins ElectricFlow Plugin, published on 11 Jun 2019. An attacker can exploit it over the internet without logging in, and only if a user opens a file or follows a link."},"fix_prompt":"Check this codebase for CVE-2019-10331 and fix it if it is affected.\n\nWhat it is: CVE-2019-10331 is a medium-severity vulnerability in Jenkins ElectricFlow Plugin, published on 11 Jun 2019. An attacker can exploit it over the internet without logging in, and only if a user opens a file or follows a link.\nExploitation: There is no known exploitation of CVE-2019-10331 in the wild and no public exploit code.\n\nAffected packages and fixed versions:\n- org.jenkins-ci.plugins:electricflow (Maven): affected all versions; fixed in 1.1.7\n- org.jenkins-ci.plugins:electricflow (Maven): affected all versions; fixed in 1.1.7\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2019-10331/ (Markdown: https://insights.sbomify.com/CVE-2019-10331/index.md)","id":"CVE-2019-10331","markdown":"https://insights.sbomify.com/CVE-2019-10331/index.md","name":"CVE-2019-10331","record":{"aliases":["GHSA-76x4-hr82-cg3m"],"analysis":{"component_type":"cms_plugin","fix_type":"upgrade","impacts":["security_bypass","data_read"],"network_reachable":"yes","non_default_config":false,"product_category":"Jenkins ElectricFlow Plugin","requires_auth":"none","summary":"Attackers can exploit CSRF to force Jenkins to connect to malicious URLs using attacker-controlled credentials via the ElectricFlow plugin.","user_interaction":"required","vuln_class":"csrf"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"jenkins","cpe":[{"product":"electricflow","vendor":"jenkins"}],"cvss":{"score":4.3,"severity":"medium","source":"nvd","vector":"CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N","version":"3.0"},"cwes":[{"id":"CWE-352","name":"Cross-Site Request Forgery"}],"description":"A cross-site request forgery vulnerability in Jenkins ElectricFlow Plugin 1.1.5 and earlier in Configuration#doTestConnection allowed attackers to connect to an attacker-specified URL using attacker-specified credentials.","ecosystems":["Maven"],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":true,"headline":"Jenkins ElectricFlow Plugin cross-site request forgery vulnerability","id":"CVE-2019-10331","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":"Maven","product":null,"products":[],"type":"csrf","year":"2019"},"n_packages":2,"n_references":3,"next":{"headline":"Jenkins ElectricFlow Plugin missing permission check","id":"CVE-2019-10332"},"packages":[{"ecosystem":"Maven","fixed":["1.1.7"],"introduced":["0"],"last_affected":[],"package":"org.jenkins-ci.plugins:electricflow","purl":null,"source":"GHSA-76x4-hr82-cg3m"},{"ecosystem":"Maven","fixed":["1.1.7"],"introduced":["0"],"last_affected":[],"package":"org.jenkins-ci.plugins:electricflow","purl":"pkg:maven/org.jenkins-ci.plugins/electricflow","source":"GHSA-76x4-hr82-cg3m"}],"prev":{"headline":"Improper handling of untrusted branches in Gitea Jenkins Plugin","id":"CVE-2019-10330"},"products":["Jenkins ElectricFlow Plugin"],"published":"2019-06-11","related":[{"cvss_score":6.5,"headline":"Jenkins ElectricFlow Plugin globally and unconditionally disabled SSL/TLS certificate validation","id":"CVE-2019-10334","kev_date_added":null,"published":"2019-06-11"},{"cvss_score":6.1,"headline":"Jenkins ElectricFlow Plugin is vulnerable to reflected cross site scripting vulnerability","id":"CVE-2019-10336","kev_date_added":null,"published":"2019-06-11"},{"cvss_score":5.4,"headline":"Jenkins ElectricFlow Plugin is vulnerable to stored cross site scripting vulnerability","id":"CVE-2019-10335","kev_date_added":null,"published":"2019-06-11"},{"cvss_score":4.3,"headline":"Jenkins ElectricFlow Plugin missing permission check","id":"CVE-2019-10332","kev_date_added":null,"published":"2019-06-11"},{"cvss_score":4.3,"headline":"Jenkins ElectricFlow Plugin Missing permission checks","id":"CVE-2019-10333","kev_date_added":null,"published":"2019-06-11"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CC BY 4.0","name":"GitHub Advisory Database","prefix":"GHSA"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-04","vendors":["Jenkins project"]},"summary":"Attackers can exploit CSRF to force Jenkins to connect to malicious URLs using attacker-controlled credentials via the ElectricFlow plugin.","url":"https://insights.sbomify.com/CVE-2019-10331/"}