CVE-2019-10918 Privilege escalation in SIMATIC PCS 7 V8.0 and earlier

High 8.8 Published Updated

Authenticated attackers can execute arbitrary commands with SYSTEM privileges via the DCOM interface in Siemens SCADA systems.

Exploited in the wild
Not known
Login needed
Any signed-in user
Attackable
Over the internet
Victim action needed
Not needed
Fix
None listed

What is CVE-2019-10918?

CVE-2019-10918 is a high-severity vulnerability in Siemens AG SIMATIC PCS 7 V8.0 and earlier, published on 14 May 2019. Any signed-in user can exploit it over the network, with no action from the victim.

Official description

A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 (All versions < V8.1 with WinCC V7.3 Upd 19), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1 with WinCC V7.4 SP1 Upd11), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP2 with WinCC V7.4 SP1 Upd11), SIMATIC WinCC (TIA Portal) V13 (All versions), SIMATIC WinCC (TIA Portal) V14 (All versions < V14 SP1 Upd 9), SIMATIC WinCC (TIA Portal) V15 (All versions < V15.1 Upd 3), SIMATIC WinCC Runtime Professional V13 (All versions), SIMATIC WinCC Runtime Professional V14 (All versions < V14.1 Upd 8), SIMATIC WinCC Runtime Professional V15 (All versions < V15.1 Upd 3), SIMATIC WinCC V7.2 and earlier (All versions), SIMATIC WinCC V7.3 (All versions < V7.3 Upd 19), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Upd 11), SIMATIC WinCC V7.5 (All versions < V7.5 Upd 3). An authenticatd attacker with network access to the DCOM interface could execute arbitrary commands with SYSTEM privileges. The vulnerability could be exploited by an attacker with network access to the affected system. Successful exploitation requires authentication with a low-privileged user account and no user interaction. An attacker could use the vulnerability to compromise confidentiality and integrity and availability of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known.

Weakness: CWE-749

Which versions are affected by CVE-2019-10918?

It affects 4 products.

Products include Siemens Simatic Pcs 7, Siemens Simatic Wincc, Siemens Simatic Wincc \(Tia Portal\), Siemens Simatic Wincc Runtime Professional.

How do I fix CVE-2019-10918?

No fix has been published for CVE-2019-10918 yet. Limit exposure of the affected software until one is available.

Is CVE-2019-10918 being exploited?

There is no known exploitation of CVE-2019-10918 in the wild and no public exploit code.

Sources

Also known as GHSA-vw33-cr89-4v6m.

Is CVE-2019-10918 in your software?

Upload an SBOM and sbomify checks it against every vulnerability here, every day.