{"answers":{"affected":"It affects 4 products.","exploited":"There is no known exploitation of CVE-2019-10918 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2019-10918 yet. Limit exposure of the affected software until one is available.","what":"CVE-2019-10918 is a high-severity vulnerability in Siemens AG SIMATIC PCS 7 V8.0 and earlier, published on 14 May 2019. Any signed-in user can exploit it over the network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2019-10918 and fix it if it is affected.\n\nWhat it is: CVE-2019-10918 is a high-severity vulnerability in Siemens AG SIMATIC PCS 7 V8.0 and earlier, published on 14 May 2019. Any signed-in user can exploit it over the network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2019-10918 in the wild and no public exploit code.\n\nAffected product: Siemens AG SIMATIC PCS 7 V8.0 and earlier. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2019-10918/ (Markdown: https://insights.sbomify.com/CVE-2019-10918/index.md)","id":"CVE-2019-10918","markdown":"https://insights.sbomify.com/CVE-2019-10918/index.md","name":"CVE-2019-10918","record":{"aliases":["GHSA-vw33-cr89-4v6m"],"analysis":{"component_type":"ics_ot","fix_type":"patch","impacts":["code_execution","privilege_escalation"],"network_reachable":"yes","non_default_config":false,"product_category":"Siemens SCADA software","requires_auth":"low_privilege","summary":"Authenticated attackers can execute arbitrary commands with SYSTEM privileges via the DCOM interface in Siemens SCADA systems.","user_interaction":"not_required","vuln_class":"privilege_escalation"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"siemens","cpe":[{"product":"simatic_pcs_7","vendor":"siemens"},{"product":"simatic_wincc","vendor":"siemens"},{"product":"simatic_wincc_\\(tia_portal\\)","vendor":"siemens"},{"product":"simatic_wincc_runtime_professional","vendor":"siemens"}],"cvss":{"score":8.8,"severity":"high","source":"nvd","vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"cwes":[{"id":"CWE-749","name":"Exposed Dangerous Method or Function"}],"description":"A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 (All versions \u003c V8.1 with WinCC V7.3 Upd 19), SIMATIC PCS 7 V8.2 (All versions \u003c V8.2 SP1 with WinCC V7.4 SP1 Upd11), SIMATIC PCS 7 V9.0 (All versions \u003c V9.0 SP2 with WinCC V7.4 SP1 Upd11), SIMATIC WinCC (TIA Portal) V13 (All versions), SIMATIC WinCC (TIA Portal) V14 (All versions \u003c V14 SP1 Upd 9), SIMATIC WinCC (TIA Portal) V15 (All versions \u003c V15.1 Upd 3), SIMATIC WinCC Runtime Professional V13 (All versions), SIMATIC WinCC Runtime Professional V14 (All versions \u003c V14.1 Upd 8), SIMATIC WinCC Runtime Professional V15 (All versions \u003c V15.1 Upd 3), SIMATIC WinCC V7.2 and earlier (All versions), SIMATIC WinCC V7.3 (All versions \u003c V7.3 Upd 19), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Upd 11), SIMATIC WinCC V7.5 (All versions \u003c V7.5 Upd 3). An authenticatd attacker with network access to the DCOM interface could execute arbitrary commands with SYSTEM privileges. The vulnerability could be exploited by an attacker with network access to the affected system. Successful exploitation requires authentication with a low-privileged user account and no user interaction. An attacker could use the vulnerability to compromise confidentiality and integrity and availability of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Privilege escalation in SIMATIC PCS 7 V8.0 and earlier","id":"CVE-2019-10918","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"privilege_escalation","year":"2019"},"n_packages":0,"n_references":2,"next":{"headline":"Missing authorization in LOGO! 8 BM (incl. SIPLUS variants)","id":"CVE-2019-10919"},"packages":[],"prev":{"headline":"Denial of service in SIMATIC PCS 7 V8.0 and earlier","id":"CVE-2019-10917"},"products":["SIMATIC PCS 7 V8.0 and earlier","SIMATIC PCS 7 V8.1","SIMATIC PCS 7 V8.2","SIMATIC PCS 7 V9.0","SIMATIC WinCC (TIA Portal) V13","SIMATIC WinCC (TIA Portal) V14","SIMATIC WinCC (TIA Portal) V15","SIMATIC WinCC Runtime Professional V13","SIMATIC WinCC Runtime Professional V14","SIMATIC WinCC Runtime Professional V15","SIMATIC WinCC V7.2 and earlier","SIMATIC WinCC V7.3","SIMATIC WinCC V7.4","SIMATIC WinCC V7.5"],"published":"2019-05-14","related":[{"cvss_score":10,"headline":"Code injection in SIMATIC PCS 7","id":"CVE-2023-25910","kev_date_added":null,"published":"2023-06-13"},{"cvss_score":9.9,"headline":"Path traversal in SIMATIC PCS 7 V8.2","id":"CVE-2021-40358","kev_date_added":null,"published":"2021-11-09"},{"cvss_score":9.8,"headline":"Auth bypass in SIMATIC PCS 7 V8.0 and earlier","id":"CVE-2019-10922","kev_date_added":null,"published":"2019-05-14"},{"cvss_score":8.8,"headline":"Information disclosure in SIMATIC PCS 7 V8.2","id":"CVE-2021-40360","kev_date_added":null,"published":"2022-02-09"},{"cvss_score":8.8,"headline":"SQL injection in SIMATIC PCS 7 V8.0 and earlier","id":"CVE-2019-10916","kev_date_added":null,"published":"2019-05-14"},{"cvss_score":8.1,"headline":"Information disclosure in SIEMENS SIMATIC WinCC (All versions \u003c SIMATIC WinCC V7.2) and SIEMENS SIMATIC PCS 7 (All versions \u003c SIMATIC PCS 7 V8.0 SP1)","id":"CVE-2016-9160","kev_date_added":null,"published":"2016-12-17"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-04","vendors":["Siemens AG"]},"summary":"Authenticated attackers can execute arbitrary commands with SYSTEM privileges via the DCOM interface in Siemens SCADA systems.","url":"https://insights.sbomify.com/CVE-2019-10918/"}