{"answers":{"affected":"It affects 2 products.","exploited":"There is no known exploitation of CVE-2019-10925 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2019-10925 yet. Limit exposure of the affected software until one is available.","what":"CVE-2019-10925 is a high-severity vulnerability in Siemens SIMATIC MV400 family, published on 12 Jun 2019. Any signed-in user can exploit it over the network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2019-10925 and fix it if it is affected.\n\nWhat it is: CVE-2019-10925 is a high-severity vulnerability in Siemens SIMATIC MV400 family, published on 12 Jun 2019. Any signed-in user can exploit it over the network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2019-10925 in the wild and no public exploit code.\n\nAffected product: Siemens SIMATIC MV400 family. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2019-10925/ (Markdown: https://insights.sbomify.com/CVE-2019-10925/index.md)","id":"CVE-2019-10925","markdown":"https://insights.sbomify.com/CVE-2019-10925/index.md","name":"CVE-2019-10925","record":{"aliases":["GHSA-978q-hc83-rf9p"],"analysis":{"component_type":"ics_ot","fix_type":"upgrade","impacts":["privilege_escalation","data_modify","denial_of_service"],"network_reachable":"yes","non_default_config":false,"product_category":"Siemens vision sensor","requires_auth":"low_privilege","summary":"An authenticated attacker can escalate privileges on Siemens SIMATIC MV400 devices via crafted web requests, compromising integrity and availability.","user_interaction":"not_required","vuln_class":"privilege_escalation"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"siemens","cpe":[{"product":"simatic_mv420_firmware","vendor":"siemens"},{"product":"simatic_mv440_firmware","vendor":"siemens"}],"cvss":{"score":7.1,"severity":"high","source":"nvd","vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:L","version":"3.1"},"cwes":[{"id":"CWE-284","name":"Improper Access Control"}],"description":"A vulnerability has been identified in SIMATIC MV400 family (All Versions \u003c V7.0.6). An authenticated attacker could escalate privileges by sending specially crafted requests to the integrated webserver. The security vulnerability can be exploited by an attacker with network access to the device. Valid user credentials, but no user interaction are required. Successful exploitation compromises integrity and availability of the device. At the time of advisory publication no public exploitation of this security vulnerability was known.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Privilege escalation in SIMATIC MV400 family","id":"CVE-2019-10925","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"privilege_escalation","year":"2019"},"n_packages":0,"n_references":3,"next":{"headline":"Information disclosure in SIMATIC MV400 family","id":"CVE-2019-10926"},"packages":[],"prev":{"headline":"Deserialization in LOGO! Soft Comfort","id":"CVE-2019-10924"},"products":["SIMATIC MV400 family"],"published":"2019-06-12","related":[{"cvss_score":7.5,"headline":"Weak cryptography in n/a","id":"CVE-2020-27632","kev_date_added":null,"published":"2021-03-10"},{"cvss_score":5.3,"headline":"Information disclosure in SIMATIC MV400 family","id":"CVE-2019-10926","kev_date_added":null,"published":"2019-06-12"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-04","vendors":["Siemens"]},"summary":"An authenticated attacker can escalate privileges on Siemens SIMATIC MV400 devices via crafted web requests, compromising integrity and availability.","url":"https://insights.sbomify.com/CVE-2019-10925/"}