{"answers":{"affected":"It affects 5 products.","exploited":"There is no known exploitation of CVE-2019-10927 in the wild and no public exploit code.","fix":"Apply the vendor's patch.","what":"CVE-2019-10927 is a medium-severity denial of service vulnerability in Siemens AG SCALANCE SC-600, published on 13 Aug 2019. Any signed-in user can exploit it over the network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2019-10927 and fix it if it is affected.\n\nWhat it is: CVE-2019-10927 is a medium-severity denial of service vulnerability in Siemens AG SCALANCE SC-600, published on 13 Aug 2019. Any signed-in user can exploit it over the network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2019-10927 in the wild and no public exploit code.\n\nAffected product: Siemens AG SCALANCE SC-600. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2019-10927/ (Markdown: https://insights.sbomify.com/CVE-2019-10927/index.md)","id":"CVE-2019-10927","markdown":"https://insights.sbomify.com/CVE-2019-10927/index.md","name":"CVE-2019-10927","record":{"aliases":["ALPINE-CVE-2019-10927","GHSA-qwf6-8cjr-7638"],"analysis":{"component_type":"network_device","fix_type":"patch","impacts":["denial_of_service"],"network_reachable":"yes","non_default_config":false,"product_category":"Siemens SCALANCE switch","requires_auth":"low_privilege","summary":"An authenticated attacker can cause a denial-of-service condition on Siemens SCALANCE network devices via port 22.","user_interaction":"not_required","vuln_class":"denial_of_service"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"siemens","cpe":[{"product":"scalance_xb-200_firmware","vendor":"siemens"},{"product":"scalance_xc-200_firmware","vendor":"siemens"},{"product":"scalance_xf-200ba_firmware","vendor":"siemens"},{"product":"scalance_xp-200_firmware","vendor":"siemens"},{"product":"scalance_xr-300wg_firmware","vendor":"siemens"}],"cvss":{"score":6.5,"severity":"medium","source":"nvd","vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H","version":"3.1"},"cwes":[{"id":"CWE-703","name":"Improper Check or Handling of Exceptional Conditions"}],"description":"A vulnerability has been identified in SCALANCE SC-600 (V2.0), SCALANCE XB-200 (V4.1), SCALANCE XC-200 (V4.1), SCALANCE XF-200BA (V4.1), SCALANCE XP-200 (V4.1), SCALANCE XR-300WG (V4.1). An authenticated attacker with network access to to port 22/tcp of an affected device may cause a Denial-of-Service condition. The security vulnerability could be exploited by an authenticated attacker with network access to the affected device. No user interaction is required to exploit this vulnerability. The vulnerability impacts the availability of the affected device.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":true,"headline":"Denial of service in SCALANCE SC-600","id":"CVE-2019-10927","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"denial_of_service","year":"2019"},"n_packages":0,"n_references":1,"next":{"headline":"Command injection in SCALANCE SC-600","id":"CVE-2019-10928"},"packages":[],"prev":{"headline":"Information disclosure in SIMATIC MV400 family","id":"CVE-2019-10926"},"products":["SCALANCE SC-600","SCALANCE XB-200","SCALANCE XC-200","SCALANCE XF-200BA","SCALANCE XP-200","SCALANCE XR-300WG"],"published":"2019-08-13","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-04","vendors":["Siemens AG"]},"summary":"An authenticated attacker can cause a denial-of-service condition on Siemens SCALANCE network devices via port 22.","url":"https://insights.sbomify.com/CVE-2019-10927/"}