{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2019-10928 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2019-10928 yet. Limit exposure of the affected software until one is available.","what":"CVE-2019-10928 is a medium-severity command injection vulnerability in Siemens AG SCALANCE SC-600, published on 13 Aug 2019. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2019-10928 and fix it if it is affected.\n\nWhat it is: CVE-2019-10928 is a medium-severity command injection vulnerability in Siemens AG SCALANCE SC-600, published on 13 Aug 2019. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2019-10928 in the wild and no public exploit code.\n\nAffected product: Siemens AG SCALANCE SC-600. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2019-10928/ (Markdown: https://insights.sbomify.com/CVE-2019-10928/index.md)","id":"CVE-2019-10928","markdown":"https://insights.sbomify.com/CVE-2019-10928/index.md","name":"CVE-2019-10928","record":{"aliases":["GHSA-m34p-92f7-v94j"],"analysis":{"component_type":"network_device","fix_type":"patch","impacts":["code_execution","privilege_escalation"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"SCALANCE SC-600","requires_auth":"low_privilege","summary":"An authenticated attacker with physical access can execute arbitrary commands on the SCALANCE SC-600 device, compromising confidentiality, integrity, and availability.","user_interaction":"not_required","vuln_class":"command_injection"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"siemens","cpe":[{"product":"scalance_sc-600_firmware","vendor":"siemens"}],"cvss":{"score":6.6,"severity":"medium","source":"nvd","vector":"CVSS:3.1/AV:P/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"cwes":[{"id":"CWE-703","name":"Improper Check or Handling of Exceptional Conditions"}],"description":"A vulnerability has been identified in SCALANCE SC-600 (V2.0). An authenticated attacker with access to port 22/tcp as well as physical access to an affected device may trigger the device to allow execution of arbitrary commands. The security vulnerability could be exploited by an authenticated attacker with physical access to the affected device. No user interaction is required to exploit this vulnerability. The vulnerability impacts the confidentiality, integrity and availability of the affected device.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Command injection in SCALANCE SC-600","id":"CVE-2019-10928","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"command_injection","year":"2019"},"n_packages":0,"n_references":1,"next":{"headline":"Security feature bypass in SIMATIC CP 1626","id":"CVE-2019-10929"},"packages":[],"prev":{"headline":"Denial of service in SCALANCE SC-600","id":"CVE-2019-10927"},"products":["SCALANCE SC-600"],"published":"2019-08-13","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-04","vendors":["Siemens AG"]},"summary":"An authenticated attacker with physical access can execute arbitrary commands on the SCALANCE SC-600 device, compromising confidentiality, integrity, and availability.","url":"https://insights.sbomify.com/CVE-2019-10928/"}