{"answers":{"affected":"It affects 4 products.","exploited":"There is no known exploitation of CVE-2019-10933 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2019-10933 yet. Limit exposure of the affected software until one is available.","what":"CVE-2019-10933 is a medium-severity cross-site scripting vulnerability in Siemens AG Spectrum Power 3 (Corporate User Interface), published on 11 Jul 2019. An attacker can exploit it over the internet without logging in, and only if a user opens a file or follows a link."},"fix_prompt":"Check this codebase for CVE-2019-10933 and fix it if it is affected.\n\nWhat it is: CVE-2019-10933 is a medium-severity cross-site scripting vulnerability in Siemens AG Spectrum Power 3 (Corporate User Interface), published on 11 Jul 2019. An attacker can exploit it over the internet without logging in, and only if a user opens a file or follows a link.\nExploitation: There is no known exploitation of CVE-2019-10933 in the wild and no public exploit code.\n\nAffected product: Siemens AG Spectrum Power 3 (Corporate User Interface). No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2019-10933/ (Markdown: https://insights.sbomify.com/CVE-2019-10933/index.md)","id":"CVE-2019-10933","markdown":"https://insights.sbomify.com/CVE-2019-10933/index.md","name":"CVE-2019-10933","record":{"aliases":["GHSA-9vrr-rmvr-4fgq"],"analysis":{"component_type":"ics_ot","fix_type":"upgrade","impacts":["security_bypass"],"network_reachable":"yes","non_default_config":false,"product_category":"Siemens Spectrum Power","requires_auth":"none","summary":"Cross-site scripting in Siemens Spectrum Power web interface allows attackers to execute scripts via malicious links, requiring user interaction.","user_interaction":"required","vuln_class":"xss"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"siemens","cpe":[{"product":"spectrum_power_3","vendor":"siemens"},{"product":"spectrum_power_4","vendor":"siemens"},{"product":"spectrum_power_5","vendor":"siemens"},{"product":"spectrum_power_7","vendor":"siemens"}],"cvss":{"score":6.1,"severity":"medium","source":"nvd","vector":"CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N","version":"3.0"},"cwes":[{"id":"CWE-79","name":"Improper Neutralization of Input During Web Page Generation"},{"id":"CWE-80","name":"Improper Neutralization of Script-Related HTML Tags in a Web Page"}],"description":"A vulnerability has been identified in Spectrum Power 3 (Corporate User Interface) (All versions \u003c= v3.11), Spectrum Power 4 (Corporate User Interface) (Version v4.75), Spectrum Power 5 (Corporate User Interface) (All versions \u003c v5.50), Spectrum Power 7 (Corporate User Interface) (All versions \u003c= v2.20). The web server could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into accessing a malicious link. User interaction is required for a successful exploitation. The user does not need to be logged into the web interface in order for the exploitation to succeed.At the stage of publishing this security advisory no public exploitation is known.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Cross-site scripting in Spectrum Power 3 (Corporate User Interface)","id":"CVE-2019-10933","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"xss","year":"2019"},"n_packages":0,"n_references":1,"next":{"headline":"Path traversal in TIA Portal V14","id":"CVE-2019-10934"},"packages":[],"prev":{"headline":"Denial of service in All other SIPROTEC 5 device types with CPU variants CP300 and CP100 and the respective Ethernet communication modules","id":"CVE-2019-10931"},"products":["Spectrum Power 3 (Corporate User Interface)","Spectrum Power 4 (Corporate User Interface)","Spectrum Power 5 (Corporate User Interface)","Spectrum Power 7 (Corporate User Interface)"],"published":"2019-07-11","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-04","vendors":["Siemens AG"]},"summary":"Cross-site scripting in Siemens Spectrum Power web interface allows attackers to execute scripts via malicious links, requiring user interaction.","url":"https://insights.sbomify.com/CVE-2019-10933/"}