{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2019-10934 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2019-10934 yet. Limit exposure of the affected software until one is available.","what":"CVE-2019-10934 is a high-severity path traversal vulnerability in Siemens TIA Portal V14, published on 16 Jan 2020. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2019-10934 and fix it if it is affected.\n\nWhat it is: CVE-2019-10934 is a high-severity path traversal vulnerability in Siemens TIA Portal V14, published on 16 Jan 2020. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2019-10934 in the wild and no public exploit code.\n\nAffected product: Siemens TIA Portal V14. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2019-10934/ (Markdown: https://insights.sbomify.com/CVE-2019-10934/index.md)","id":"CVE-2019-10934","markdown":"https://insights.sbomify.com/CVE-2019-10934/index.md","name":"CVE-2019-10934","record":{"aliases":["GHSA-62j2-rqpv-q83g"],"analysis":{"component_type":"desktop_application","fix_type":"upgrade","impacts":["code_execution","privilege_escalation"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Siemens TIA Portal","requires_auth":"low_privilege","summary":"An attacker with limited access can modify a configuration file to execute arbitrary code with SYSTEM privileges in Siemens TIA Portal.","user_interaction":"not_required","vuln_class":"path_traversal"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"siemens","cpe":[{"product":"totally_integrated_automation_portal","vendor":"siemens"}],"cvss":{"score":7.8,"severity":"high","source":"nvd","vector":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"cwes":[{"id":"CWE-22","name":"Improper Limitation of a Pathname to a Restricted Directory"}],"description":"A vulnerability has been identified in TIA Portal V14 (All versions), TIA Portal V15 (All versions \u003c V15.1 Update 7), TIA Portal V16 (All versions \u003c V16 Update 6), TIA Portal V17 (All versions \u003c V17 Update 4). Changing the contents of a configuration file could allow an attacker to execute arbitrary code with SYSTEM privileges. The security vulnerability could be exploited by an attacker with a valid account and limited access rights on the system. No user interaction is required. At the time of advisory publication no public exploitation of this security vulnerability was known.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Path traversal in TIA Portal V14","id":"CVE-2019-10934","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"path_traversal","year":"2019"},"n_packages":0,"n_references":1,"next":{"headline":"File upload in SIMATIC PCS 7 V8.0 and earlier","id":"CVE-2019-10935"},"packages":[],"prev":{"headline":"Cross-site scripting in Spectrum Power 3 (Corporate User Interface)","id":"CVE-2019-10933"},"products":["TIA Portal V14","TIA Portal V15","TIA Portal V16","TIA Portal V17"],"published":"2020-01-16","related":[{"cvss_score":6.2,"headline":"A vulnerability has been identified in Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation P","id":"CVE-2023-30757","kev_date_added":null,"published":"2023-06-13"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-04","vendors":["Siemens"]},"summary":"An attacker with limited access can modify a configuration file to execute arbitrary code with SYSTEM privileges in Siemens TIA Portal.","url":"https://insights.sbomify.com/CVE-2019-10934/"}