{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2019-10938 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2019-10938 yet. Limit exposure of the affected software until one is available.","what":"CVE-2019-10938 is a critical code injection vulnerability in Siemens AG SIPROTEC 5 devices with CPU variants CP200, published on 2 Aug 2019. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2019-10938 and fix it if it is affected.\n\nWhat it is: CVE-2019-10938 is a critical code injection vulnerability in Siemens AG SIPROTEC 5 devices with CPU variants CP200, published on 2 Aug 2019. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2019-10938 in the wild and no public exploit code.\n\nAffected product: Siemens AG SIPROTEC 5 devices with CPU variants CP200. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2019-10938/ (Markdown: https://insights.sbomify.com/CVE-2019-10938/index.md)","id":"CVE-2019-10938","markdown":"https://insights.sbomify.com/CVE-2019-10938/index.md","name":"CVE-2019-10938","record":{"aliases":["GHSA-5vvv-cppj-rx9m"],"analysis":{"component_type":"ics_ot","fix_type":"upgrade","impacts":["code_execution"],"network_reachable":"yes","non_default_config":false,"product_category":"Siemens SIPROTEC 5","requires_auth":"none","summary":"An unauthenticated attacker can inject arbitrary code executed before firmware verification on Siemens SIPROTEC 5 devices and power meters.","user_interaction":"not_required","vuln_class":"code_injection"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"siemens","cpe":[{"product":"siprotec_5_digsi_device_driver","vendor":"siemens"}],"cvss":{"score":9.8,"severity":"critical","source":"nvd","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"cwes":[{"id":"CWE-284","name":"Improper Access Control"}],"description":"A vulnerability has been identified in SIPROTEC 5 devices with CPU variants CP200 (All versions \u003c V7.59), SIPROTEC 5 devices with CPU variants CP300 and CP100 (All versions \u003c V8.01), Siemens Power Meters Series 9410 (All versions \u003c V2.2.1), Siemens Power Meters Series 9810 (All versions). An unauthenticated attacker with network access to the device could potentially insert arbitrary code which is executed before firmware verification in the device. At the time of advisory publication no public exploitation of this security vulnerability was known.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Code injection in SIPROTEC 5 devices with CPU variants CP200","id":"CVE-2019-10938","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"code_injection","year":"2019"},"n_packages":0,"n_references":2,"next":{"headline":"A vulnerability has been identified in TIM 3V-IE (incl.","id":"CVE-2019-10939"},"packages":[],"prev":{"headline":"Denial of service in SIMATIC TDC CP51M1","id":"CVE-2019-10937"},"products":["SIPROTEC 5 devices with CPU variants CP200","SIPROTEC 5 devices with CPU variants CP300 and CP100","Siemens Power Meters Series 9410","Siemens Power Meters Series 9810"],"published":"2019-08-02","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-04","vendors":["Siemens AG"]},"summary":"An unauthenticated attacker can inject arbitrary code executed before firmware verification on Siemens SIPROTEC 5 devices and power meters.","url":"https://insights.sbomify.com/CVE-2019-10938/"}