{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2019-10941 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2019-10941 yet. Limit exposure of the affected software until one is available.","what":"CVE-2019-10941 is a medium-severity missing authorization vulnerability in Siemens SINEMA Server, published on 14 Sep 2021. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2019-10941 and fix it if it is affected.\n\nWhat it is: CVE-2019-10941 is a medium-severity missing authorization vulnerability in Siemens SINEMA Server, published on 14 Sep 2021. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2019-10941 in the wild and no public exploit code.\n\nAffected product: Siemens SINEMA Server. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2019-10941/ (Markdown: https://insights.sbomify.com/CVE-2019-10941/index.md)","id":"CVE-2019-10941","markdown":"https://insights.sbomify.com/CVE-2019-10941/index.md","name":"CVE-2019-10941","record":{"aliases":["GHSA-69h3-7gjf-m5gx"],"analysis":{"component_type":"server_software","fix_type":"upgrade","impacts":["data_read"],"network_reachable":"yes","non_default_config":false,"product_category":"Siemens SINEMA Server","requires_auth":"none","summary":"An unauthenticated attacker can access encoded system configuration backups via network access due to missing authentication checks.","user_interaction":"not_required","vuln_class":"missing_authorization"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"siemens","cpe":[{"product":"sinema_server","vendor":"siemens"}],"cvss":{"score":5.3,"severity":"medium","source":"nvd","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N","version":"3.1"},"cwes":[{"id":"CWE-306","name":"Missing Authentication for Critical Functionality"}],"description":"A vulnerability has been identified in SINEMA Server (All versions \u003c V14 SP3). Missing authentication for functionality that requires administrative user identity could allow an attacker to obtain encoded system configuration backup files. This is only possible through network access to the affected system, and successful exploitation requires no system privileges.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Missing authorization in SINEMA Server","id":"CVE-2019-10941","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"missing_authorization","year":"2019"},"n_packages":0,"n_references":1,"next":{"headline":"Denial of service in SCALANCE X-200 switch family (incl. SIPLUS NET variants)","id":"CVE-2019-10942"},"packages":[],"prev":{"headline":"Privilege escalation in SINEMA Server","id":"CVE-2019-10940"},"products":["SINEMA Server"],"published":"2021-09-14","related":[{"cvss_score":9.9,"headline":"Privilege escalation in SINEMA Server","id":"CVE-2019-10940","kev_date_added":null,"published":"2020-01-16"},{"cvss_score":9.3,"headline":"Code injection in n/a","id":"CVE-2014-2731","kev_date_added":null,"published":"2014-04-19"},{"cvss_score":8.3,"headline":"Cross-site scripting in SINEMA Server V14","id":"CVE-2023-35796","kev_date_added":null,"published":"2023-10-10"},{"cvss_score":7.8,"headline":"Privilege escalation in n/a","id":"CVE-2016-6486","kev_date_added":null,"published":"2016-08-08"},{"cvss_score":5,"headline":"Path traversal in n/a","id":"CVE-2014-2732","kev_date_added":null,"published":"2014-04-19"},{"cvss_score":5,"headline":"Denial of service in n/a","id":"CVE-2014-2733","kev_date_added":null,"published":"2014-04-19"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-04","vendors":["Siemens"]},"summary":"An unauthenticated attacker can access encoded system configuration backups via network access due to missing authentication checks.","url":"https://insights.sbomify.com/CVE-2019-10941/"}