{"answers":{"affected":"It affects 3 products.","exploited":"There is no known exploitation of CVE-2019-10950 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2019-10950 yet. Limit exposure of the affected software until one is available.","what":"CVE-2019-10950 is a critical authentication bypass vulnerability in Fujifilm FCR Capsula X/ Carbon X, published on 30 Apr 2019. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2019-10950 and fix it if it is affected.\n\nWhat it is: CVE-2019-10950 is a critical authentication bypass vulnerability in Fujifilm FCR Capsula X/ Carbon X, published on 30 Apr 2019. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2019-10950 in the wild and no public exploit code.\n\nAffected product: Fujifilm FCR Capsula X/ Carbon X. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2019-10950/ (Markdown: https://insights.sbomify.com/CVE-2019-10950/index.md)","id":"CVE-2019-10950","markdown":"https://insights.sbomify.com/CVE-2019-10950/index.md","name":"CVE-2019-10950","record":{"aliases":["GHSA-2rcq-4r2f-jhv9"],"analysis":{"component_type":"ics_ot","fix_type":"no_fix_stated","impacts":["privilege_escalation","code_execution"],"network_reachable":"yes","non_default_config":false,"product_category":"Medical imaging device","requires_auth":"none","summary":"Attackers can access the underlying operating system of Fujifilm medical imaging devices via unauthenticated telnet services.","user_interaction":"not_required","vuln_class":"auth_bypass"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[{"product":"cr-ir_357_fcr_capsula_x_firmware","vendor":"fujifilm"},{"product":"cr-ir_357_fcr_carbon_x_firmware","vendor":"fujifilm"},{"product":"cr-ir_357_fcr_xc-2_firmware","vendor":"fujifilm"}],"cvss":{"score":9.8,"severity":"critical","source":"nvd","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"cwes":[{"id":"CWE-306","name":"Missing Authentication for Critical Functionality"},{"id":"CWE-284","name":"Improper Access Control"}],"description":"Fujifilm FCR Capsula X/ Carbon X/ FCR XC-2, model versions CR-IR 357 FCR Carbon X, CR-IR 357 FCR XC-2, FCR-IR 357 FCR Capsula X provide insecure telnet services that lack authentication requirements. An attacker who successfully exploits this vulnerability may be able to access the underlying operating system.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Auth bypass in Fujifilm FCR Capsula X/ Carbon X","id":"CVE-2019-10950","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"auth_bypass","year":"2019"},"n_packages":0,"n_references":2,"next":{"headline":"Memory corruption in Delta Industrial Automation CNCSoft","id":"CVE-2019-10951"},"packages":[],"prev":{"headline":"Information disclosure in Delta Industrial Automation CNCSoft","id":"CVE-2019-10949"},"products":["Fujifilm FCR Capsula X/ Carbon X"],"published":"2019-04-30","related":[{"cvss_score":7.5,"headline":"Denial of service in Fujifilm FCR Capsula X/ Carbon X","id":"CVE-2019-10948","kev_date_added":null,"published":"2019-04-30"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-04","vendors":["Fujifilm"]},"summary":"Attackers can access the underlying operating system of Fujifilm medical imaging devices via unauthenticated telnet services.","url":"https://insights.sbomify.com/CVE-2019-10950/"}