{"answers":{"affected":"It affects 19 products.","exploited":"There is no known exploitation of CVE-2019-10964 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2019-10964 yet. Limit exposure of the affected software until one is available.","what":"CVE-2019-10964 is a high-severity missing authorization vulnerability in Medtronic MiniMed 508 pump, published on 28 Jun 2019. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2019-10964 and fix it if it is affected.\n\nWhat it is: CVE-2019-10964 is a high-severity missing authorization vulnerability in Medtronic MiniMed 508 pump, published on 28 Jun 2019. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2019-10964 in the wild and no public exploit code.\n\nAffected product: Medtronic MiniMed 508 pump. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2019-10964/ (Markdown: https://insights.sbomify.com/CVE-2019-10964/index.md)","id":"CVE-2019-10964","markdown":"https://insights.sbomify.com/CVE-2019-10964/index.md","name":"CVE-2019-10964","record":{"aliases":["GHSA-54f2-q9g6-3cvc"],"analysis":{"component_type":"iot_embedded","fix_type":"no_fix_stated","impacts":["data_modify","privilege_escalation"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Medtronic insulin pump","requires_auth":"none","summary":"Attackers with adjacent access can bypass authentication to modify insulin pump settings and control insulin delivery via insecure RF communication.","user_interaction":"not_required","vuln_class":"missing_authorization"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[{"product":"minimed_508_firmware","vendor":"medtronic"},{"product":"minimed_paradigm_511_firmware","vendor":"medtronic"},{"product":"minimed_paradigm_512_firmware","vendor":"medtronic"},{"product":"minimed_paradigm_515_firmware","vendor":"medtronic"},{"product":"minimed_paradigm_522_firmware","vendor":"medtronic"},{"product":"minimed_paradigm_522k_firmware","vendor":"medtronic"},{"product":"minimed_paradigm_523_firmware","vendor":"medtronic"},{"product":"minimed_paradigm_523k_firmware","vendor":"medtronic"},{"product":"minimed_paradigm_712_firmware","vendor":"medtronic"},{"product":"minimed_paradigm_712e_firmware","vendor":"medtronic"},{"product":"minimed_paradigm_715_firmware","vendor":"medtronic"},{"product":"minimed_paradigm_722_firmware","vendor":"medtronic"},{"product":"minimed_paradigm_722k_firmware","vendor":"medtronic"},{"product":"minimed_paradigm_723_firmware","vendor":"medtronic"},{"product":"minimed_paradigm_723k_firmware","vendor":"medtronic"},{"product":"minimed_paradigm_veo_554_firmware","vendor":"medtronic"},{"product":"minimed_paradigm_veo_554cm_firmware","vendor":"medtronic"},{"product":"minimed_paradigm_veo_754_firmware","vendor":"medtronic"},{"product":"minimed_paradigm_veo_754cm_firmware","vendor":"medtronic"}],"cvss":{"score":7.1,"severity":"high","source":"cna","vector":"CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:L/I:H/A:H","version":"3.1"},"cwes":[{"id":"CWE-863","name":"Incorrect Authorization"},{"id":"CWE-287","name":"Improper Authentication"},{"id":"CWE-284","name":"Improper Access Control"}],"description":"Medtronic MiniMed Insulin Pumps\n\n are designed to communicate using a wireless RF with other devices, such as blood glucose meters, glucose sensor transmitters, and CareLink USB devices. This wireless RF communication protocol does not properly implement authentication or authorization. An attacker with adjacent access to one of the affected insulin pump models can inject, replay, modify, and/or intercept data. This vulnerability could also allow attackers to change pump settings and control insulin delivery.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Medtronic MiniMed 508 and Paradigm Series Insulin Pumps Improper Access Control","id":"CVE-2019-10964","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"missing_authorization","year":"2019"},"n_packages":0,"n_references":3,"next":{"headline":"Memory corruption in Emerson Ovation OCR400 Controller","id":"CVE-2019-10965"},"packages":[],"prev":{"headline":"Information disclosure in Moxa EDR 810","id":"CVE-2019-10963"},"products":["MiniMed 508 pump","MiniMed Paradigm 511 pump","MiniMed Paradigm 512/712 pumps","MiniMed Paradigm 515/715 pumps","MiniMed Paradigm 522/722 pumps","MiniMed Paradigm 522K/722K pumps","MiniMed Paradigm 523/723 pumps","MiniMed Paradigm 523K/723K pumps","MiniMed Paradigm 712E pump","MiniMed Paradigm Veo 554/754 pumps","MiniMed Paradigm Veo 554CM/754CM pumps"],"published":"2019-06-28","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2025-05-22","vendors":["Medtronic"]},"summary":"Attackers with adjacent access can bypass authentication to modify insulin pump settings and control insulin delivery via insecure RF communication.","url":"https://insights.sbomify.com/CVE-2019-10964/"}