{"answers":{"affected":"It affects 8 products.","exploited":"There is no known exploitation of CVE-2019-10995 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2019-10995 yet. Limit exposure of the affected software until one is available.","what":"CVE-2019-10995 is a high-severity vulnerability in ABB CP651 HMI products, published on 14 Jan 2020. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2019-10995 and fix it if it is affected.\n\nWhat it is: CVE-2019-10995 is a high-severity vulnerability in ABB CP651 HMI products, published on 14 Jan 2020. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2019-10995 in the wild and no public exploit code.\n\nAffected product: ABB CP651 HMI products. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2019-10995/ (Markdown: https://insights.sbomify.com/CVE-2019-10995/index.md)","id":"CVE-2019-10995","markdown":"https://insights.sbomify.com/CVE-2019-10995/index.md","name":"CVE-2019-10995","record":{"aliases":["GHSA-6qrc-v8hx-x5f6"],"analysis":{"component_type":"ics_ot","fix_type":"patch","impacts":["privilege_escalation","account_takeover"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"ABB CP651 HMI","requires_auth":"none","summary":"Hidden administrative accounts in ABB CP651 HMIs allow attackers to gain unauthorized privileged access to the interface.","user_interaction":"not_required","vuln_class":"hardcoded_credentials"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[{"product":"cp651-web_firmware","vendor":"abb"},{"product":"cp651_firmware","vendor":"abb"},{"product":"cp661-web_firmware","vendor":"abb"},{"product":"cp661_firmware","vendor":"abb"},{"product":"cp665-web_firmware","vendor":"abb"},{"product":"cp665_firmware","vendor":"abb"},{"product":"cp676-web_firmware","vendor":"abb"},{"product":"cp676_firmware","vendor":"abb"}],"cvss":{"score":8.8,"severity":"high","source":"nvd","vector":"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"cwes":[{"id":"CWE-798","name":"Use of Hard-coded Credentials"}],"description":"ABB CP651 HMI products revision BSP UN30 v1.76 and prior implement hidden administrative accounts that are used during the provisioning phase of the HMI interface.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Hardcoded credentials in ABB CP651 HMI products","id":"CVE-2019-10995","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"hardcoded_credentials","year":"2019"},"n_packages":0,"n_references":2,"next":{"headline":"Use after free in Red Lion Controls Crimson (Windows configuration software)","id":"CVE-2019-10996"},"packages":[],"prev":{"headline":"Information disclosure in LCDS LAquis SCADA","id":"CVE-2019-10994"},"products":["ABB CP651 HMI products"],"published":"2020-01-14","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-04","vendors":["n/a"]},"summary":"Hidden administrative accounts in ABB CP651 HMIs allow attackers to gain unauthorized privileged access to the interface.","url":"https://insights.sbomify.com/CVE-2019-10995/"}