{"answers":{"affected":"It affects 12 products.","exploited":"There is no known exploitation of CVE-2019-12265 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2019-12265 yet. Limit exposure of the affected software until one is available.","what":"CVE-2019-12265 is a medium-severity vulnerability in Netapp E-Series Santricity Os Controller, published on 9 Aug 2019. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2019-12265 and fix it if it is affected.\n\nWhat it is: CVE-2019-12265 is a medium-severity vulnerability in Netapp E-Series Santricity Os Controller, published on 9 Aug 2019. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2019-12265 in the wild and no public exploit code.\n\nAffected product: Netapp E-Series Santricity Os Controller. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2019-12265/ (Markdown: https://insights.sbomify.com/CVE-2019-12265/index.md)","id":"CVE-2019-12265","markdown":"https://insights.sbomify.com/CVE-2019-12265/index.md","name":"CVE-2019-12265","record":{"aliases":["GHSA-pwq9-w59r-4v6m"],"analysis":{"component_type":"operating_system","fix_type":"patch","impacts":["data_read"],"network_reachable":"yes","non_default_config":false,"product_category":"VxWorks RTOS","requires_auth":"none","summary":"An attacker can cause a memory leak in the IGMPv3 client, leading to information disclosure in Wind River VxWorks systems.","user_interaction":"not_required","vuln_class":"information_disclosure"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"mitre","cpe":[{"product":"garrettcom_magnum_dx940e_firmware","vendor":"belden"},{"product":"hirschmann_hios","vendor":"belden"},{"product":"e-series_santricity_os_controller","vendor":"netapp"},{"product":"power_meter_9410_firmware","vendor":"siemens"},{"product":"power_meter_9810_firmware","vendor":"siemens"},{"product":"ruggedcom_win7000_firmware","vendor":"siemens"},{"product":"ruggedcom_win7018_firmware","vendor":"siemens"},{"product":"ruggedcom_win7025_firmware","vendor":"siemens"},{"product":"ruggedcom_win7200_firmware","vendor":"siemens"},{"product":"siprotec_5_firmware","vendor":"siemens"},{"product":"sonicos","vendor":"sonicwall"},{"product":"vxworks","vendor":"windriver"}],"cvss":{"score":5.3,"severity":"medium","source":"nvd","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N","version":"3.1"},"cwes":[{"id":"CWE-401","name":"Missing Release of Memory after Effective Lifetime"}],"description":"Wind River VxWorks 6.5, 6.6, 6.7, 6.8, 6.9.3 and 6.9.4 has a Memory Leak in the IGMPv3 client component. There is an IPNET security vulnerability: IGMP Information leak via IGMPv3 specific membership report.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Information disclosure in n/a","id":"CVE-2019-12265","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":"netapp:e-series_santricity_os_controller","products":["netapp:e-series_santricity_os_controller","sonicwall:sonicos"],"type":"information_disclosure","year":"2019"},"n_packages":0,"n_references":9,"next":{"headline":"Stack buffer overflow in Wyze Cam Pan v2, Cam v2 and Cam v3","id":"CVE-2019-12266"},"packages":[],"prev":{"headline":"Missing authorization in n/a","id":"CVE-2019-12264"},"products":["n/a"],"published":"2019-08-09","related":[{"cvss_score":9.8,"headline":"Missing authorization in n/a","id":"CVE-2019-12262","kev_date_added":null,"published":"2019-08-14"},{"cvss_score":9.8,"headline":"Integer overflow in n/a","id":"CVE-2019-12255","kev_date_added":null,"published":"2019-08-09"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2019-12256","kev_date_added":null,"published":"2019-08-09"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2019-12260","kev_date_added":null,"published":"2019-08-09"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2019-12261","kev_date_added":null,"published":"2019-08-09"},{"cvss_score":8.8,"headline":"Memory corruption in n/a","id":"CVE-2019-12257","kev_date_added":null,"published":"2019-08-09"},{"cvss_score":8.1,"headline":"Race condition in n/a","id":"CVE-2019-12263","kev_date_added":null,"published":"2019-08-09"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-04","vendors":["n/a"]},"summary":"An attacker can cause a memory leak in the IGMPv3 client, leading to information disclosure in Wind River VxWorks systems.","url":"https://insights.sbomify.com/CVE-2019-12265/"}