CVE-2019-12310 Path traversal in n/a

Critical 9.8 Published Updated

Remote attackers can exploit a path traversal flaw to retrieve sensitive logs containing credentials, leading to administrative access on ExaGrid appliances.

Exploited in the wild
Not known
Login needed
Not needed
Attackable
Over the internet
Victim action needed
Not needed
Fix
None listed

What is CVE-2019-12310?

CVE-2019-12310 is a critical path traversal vulnerability in n/a, published on 3 Jun 2019. An attacker can exploit it over the internet without logging in, with no action from the victim.

Official description

ExaGrid appliances with firmware version v4.8.1.1044.P50 have a /monitor/data/Upgrade/ directory traversal vulnerability, which allows remote attackers to view and retrieve verbose logging information. Files within this directory were observed to contain sensitive run-time information, including Base64 encoded 'support' credentials, leading to administrative access of the device.

Weakness: CWE-22

Which versions are affected by CVE-2019-12310?

It affects 1 product.

Products include Exagrid Backup Appliance Firmware.

How do I fix CVE-2019-12310?

No fix has been published for CVE-2019-12310 yet. Limit exposure of the affected software until one is available.

Upgrade, and resolve every user-supplied path against an allowed base folder before opening it. More about Path traversal.

Is CVE-2019-12310 being exploited?

There is no known exploitation of CVE-2019-12310 in the wild and no public exploit code.