{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2019-12720 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2019-12720 yet. Limit exposure of the affected software until one is available.","what":"CVE-2019-12720 is a high-severity SQL injection vulnerability in n/a, published on 12 Nov 2019. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2019-12720 and fix it if it is affected.\n\nWhat it is: CVE-2019-12720 is a high-severity SQL injection vulnerability in n/a, published on 12 Nov 2019. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2019-12720 in the wild and no public exploit code.\n\nAffected product: n/a. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2019-12720/ (Markdown: https://insights.sbomify.com/CVE-2019-12720/index.md)","id":"CVE-2019-12720","markdown":"https://insights.sbomify.com/CVE-2019-12720/index.md","name":"CVE-2019-12720","record":{"aliases":["GHSA-fpcm-j34w-8cjw"],"analysis":{"component_type":"web_application","fix_type":"upgrade","impacts":["data_read"],"network_reachable":"yes","non_default_config":false,"product_category":"AUO SunVeillance Monitoring","requires_auth":"none","summary":"An attacker can exploit SQL injection vulnerabilities in AUO SunVeillance Monitoring System to read privileged data from the server.","user_interaction":"not_required","vuln_class":"sql_injection"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"mitre","cpe":[{"product":"sunveillance_monitoring_system_\\\u0026_data_recorder","vendor":"auo"}],"cvss":{"score":7.5,"severity":"high","source":"nvd","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","version":"3.1"},"cwes":[{"id":"CWE-89","name":"Improper Neutralization of Special Elements used in an SQL Command"}],"description":"AUO SunVeillance Monitoring System before v1.1.9e is vulnerable to mvc_send_mail.aspx (MailAdd parameter) SQL Injection. An Attacker can carry a SQL Injection payload to the server, allowing the attacker to read privileged data. This also affects the picture_manage_mvc.aspx plant_no parameter, the swapdl_mvc.aspx plant_no parameter, and the account_management.aspx Text_Postal_Code and Text_Dis_Code parameters.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"SQL injection in n/a","id":"CVE-2019-12720","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"sql_injection","year":"2019"},"n_packages":0,"n_references":2,"next":{"headline":"SQL injection in n/a","id":"CVE-2019-12723"},"packages":[],"prev":{"headline":"File upload in n/a","id":"CVE-2019-12719"},"products":["n/a"],"published":"2019-11-12","related":[{"cvss_score":9.8,"headline":"File upload in n/a","id":"CVE-2019-12719","kev_date_added":null,"published":"2019-11-12"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-04","vendors":["n/a"]},"summary":"An attacker can exploit SQL injection vulnerabilities in AUO SunVeillance Monitoring System to read privileged data from the server.","url":"https://insights.sbomify.com/CVE-2019-12720/"}