{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2019-13140 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2019-13140 yet. Limit exposure of the affected software until one is available.","what":"CVE-2019-13140 is a medium-severity vulnerability in n/a, published on 16 Sep 2019. Any signed-in user can exploit it over the network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2019-13140 and fix it if it is affected.\n\nWhat it is: CVE-2019-13140 is a medium-severity vulnerability in n/a, published on 16 Sep 2019. Any signed-in user can exploit it over the network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2019-13140 in the wild and no public exploit code.\n\nAffected product: n/a. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2019-13140/ (Markdown: https://insights.sbomify.com/CVE-2019-13140/index.md)","id":"CVE-2019-13140","markdown":"https://insights.sbomify.com/CVE-2019-13140/index.md","name":"CVE-2019-13140","record":{"aliases":["GHSA-h69c-wc8m-xgv4"],"analysis":{"component_type":"network_device","fix_type":"no_fix_stated","impacts":["data_read","security_bypass"],"network_reachable":"yes","non_default_config":false,"product_category":"Inteno EG200 router","requires_auth":"low_privilege","summary":"A misconfiguration in Inteno EG200 routers allows low-privilege users to extract the 3DES key, enabling decryption of sensitive provisioning data.","user_interaction":"not_required","vuln_class":"information_disclosure"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"mitre","cpe":[{"product":"eg200_firmware","vendor":"intenogroup"}],"cvss":{"score":6.5,"severity":"medium","source":"nvd","vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N","version":"3.1"},"cwes":[{"id":"CWE-552","name":"Files or Directories Accessible to External Parties"}],"description":"Inteno EG200 EG200-WU7P1U_ADAMO3.16.4-190226_1650 routers have a JUCI ACL misconfiguration that allows the \"user\" account to extract the 3DES key via JSON commands to ubus. The 3DES key is used to decrypt the provisioning file provided by Adamo Telecom on a public URL via cleartext HTTP.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Information disclosure in n/a","id":"CVE-2019-13140","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"information_disclosure","year":"2019"},"n_packages":0,"n_references":4,"next":{"headline":"Privilege escalation in n/a","id":"CVE-2019-13142"},"packages":[],"prev":{"headline":"Command injection in n/a","id":"CVE-2019-13139"},"products":["n/a"],"published":"2019-09-16","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-04","vendors":["n/a"]},"summary":"A misconfiguration in Inteno EG200 routers allows low-privilege users to extract the 3DES key, enabling decryption of sensitive provisioning data.","url":"https://insights.sbomify.com/CVE-2019-13140/"}