{"answers":{"affected":"It affects 59 products.","exploited":"There is no known exploitation of CVE-2019-13523 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2019-13523 yet. Limit exposure of the affected software until one is available.","what":"CVE-2019-13523 is a medium-severity missing authorization vulnerability in Honeywell Performance IP Cameras, published on 26 Sep 2019. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2019-13523 and fix it if it is affected.\n\nWhat it is: CVE-2019-13523 is a medium-severity missing authorization vulnerability in Honeywell Performance IP Cameras, published on 26 Sep 2019. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2019-13523 in the wild and no public exploit code.\n\nAffected product: Honeywell Performance IP Cameras. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2019-13523/ (Markdown: https://insights.sbomify.com/CVE-2019-13523/index.md)","id":"CVE-2019-13523","markdown":"https://insights.sbomify.com/CVE-2019-13523/index.md","name":"CVE-2019-13523","record":{"aliases":["GHSA-6j5f-pm23-xcwq"],"analysis":{"component_type":"iot_embedded","fix_type":"no_fix_stated","impacts":["data_read"],"network_reachable":"yes","non_default_config":false,"product_category":"Honeywell IP Cameras","requires_auth":"none","summary":"Remote attackers can access sensitive web configuration data without authentication on Honeywell Performance IP Cameras and NVRs.","user_interaction":"not_required","vuln_class":"missing_authorization"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[{"product":"h2w2pc1m_firmware","vendor":"honeywell"},{"product":"h2w2per3_firmware","vendor":"honeywell"},{"product":"h2w4per3_firmware","vendor":"honeywell"},{"product":"h4d3prv2_firmware","vendor":"honeywell"},{"product":"h4d3prv3_firmware","vendor":"honeywell"},{"product":"h4w2per2_firmware","vendor":"honeywell"},{"product":"h4w2per3_firmware","vendor":"honeywell"},{"product":"h4w8pr2_firmware","vendor":"honeywell"},{"product":"hbd3pr1_firmware","vendor":"honeywell"},{"product":"hbd3pr2_firmware","vendor":"honeywell"},{"product":"hbw2per1_firmware","vendor":"honeywell"},{"product":"hbw2per2_firmware","vendor":"honeywell"},{"product":"hbw8pr2_firmware","vendor":"honeywell"},{"product":"hed3pr3_firmware","vendor":"honeywell"},{"product":"hen04103_firmware","vendor":"honeywell"},{"product":"hen04103l_firmware","vendor":"honeywell"},{"product":"hen04113_firmware","vendor":"honeywell"},{"product":"hen04123_firmware","vendor":"honeywell"},{"product":"hen08103_firmware","vendor":"honeywell"},{"product":"hen08103l_firmware","vendor":"honeywell"},{"product":"hen08104_firmware","vendor":"honeywell"},{"product":"hen081124_firmware","vendor":"honeywell"},{"product":"hen08113_firmware","vendor":"honeywell"},{"product":"hen08123_firmware","vendor":"honeywell"},{"product":"hen08143_firmware","vendor":"honeywell"},{"product":"hen08144_firmware","vendor":"honeywell"},{"product":"hen16103_firmware","vendor":"honeywell"},{"product":"hen16103l_firmware","vendor":"honeywell"},{"product":"hen16104_firmware","vendor":"honeywell"},{"product":"hen16123_firmware","vendor":"honeywell"},{"product":"hen16143_firmware","vendor":"honeywell"},{"product":"hen16144_firmware","vendor":"honeywell"},{"product":"hen16163_firmware","vendor":"honeywell"},{"product":"hen16184_firmware","vendor":"honeywell"},{"product":"hen16204_firmware","vendor":"honeywell"},{"product":"hen162244_firmware","vendor":"honeywell"},{"product":"hen16284_firmware","vendor":"honeywell"},{"product":"hen16304_firmware","vendor":"honeywell"},{"product":"hen16384_firmware","vendor":"honeywell"},{"product":"hen32103l_firmware","vendor":"honeywell"},{"product":"hen32104_firmware","vendor":"honeywell"},{"product":"hen321124_firmware","vendor":"honeywell"},{"product":"hen32204_firmware","vendor":"honeywell"},{"product":"hen322164_firmware","vendor":"honeywell"},{"product":"hen32284_firmware","vendor":"honeywell"},{"product":"hen32304_firmware","vendor":"honeywell"},{"product":"hen323164_firmware","vendor":"honeywell"},{"product":"hen32384_firmware","vendor":"honeywell"},{"product":"hen64204_firmware","vendor":"honeywell"},{"product":"hen64304_firmware","vendor":"honeywell"},{"product":"hen643164_firmware","vendor":"honeywell"},{"product":"hen643324_firmware","vendor":"honeywell"},{"product":"hen643484_firmware","vendor":"honeywell"},{"product":"hew2per2_firmware","vendor":"honeywell"},{"product":"hew2per3_firmware","vendor":"honeywell"},{"product":"hew4per2_firmware","vendor":"honeywell"},{"product":"hew4per2b_firmware","vendor":"honeywell"},{"product":"hew4per3b_firmware","vendor":"honeywell"},{"product":"hpw2p1_firmware","vendor":"honeywell"}],"cvss":{"score":5.3,"severity":"medium","source":"nvd","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N","version":"3.1"},"cwes":[{"id":"CWE-306","name":"Missing Authentication for Critical Functionality"},{"id":"CWE-200","name":"Exposure of Sensitive Information to an Unauthorized Actor"}],"description":"In Honeywell Performance IP Cameras and Performance NVRs, the integrated web server of the affected devices could allow remote attackers to obtain web configuration data in JSON format for IP cameras and NVRs (Network Video Recorders), which can be accessed without authentication over the network. Affected performance IP Cameras: HBD3PR2,H4D3PRV3,HED3PR3,H4D3PRV2,HBD3PR1,H4W8PR2,HBW8PR2,H2W2PC1M,H2W4PER3,H2W2PER3,HEW2PER3,HEW4PER3B,HBW2PER1,HEW4PER2,HEW4PER2B,HEW2PER2,H4W2PER2,HBW2PER2,H4W2PER3, and HPW2P1. Affected Performance Series NVRs: HEN08104,HEN08144,HEN081124,HEN16104,HEN16144,HEN16184,HEN16204,HEN162244,HEN16284,HEN16304,HEN16384,HEN32104,HEN321124,HEN32204,HEN32284,HEN322164,HEN32304, HEN32384,HEN323164,HEN64204,HEN64304,HEN643164,HEN643324,HEN643484,HEN04103,HEN04113,HEN04123,HEN08103,HEN08113,HEN08123,HEN08143,HEN16103,HEN16123,HEN16143,HEN16163,HEN04103L,HEN08103L,HEN16103L,HEN32103L.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Missing authorization in Performance IP Cameras","id":"CVE-2019-13523","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"missing_authorization","year":"2019"},"n_packages":0,"n_references":1,"next":{"headline":"Denial of service in GE PACSystems RX3i","id":"CVE-2019-13524"},"packages":[],"prev":{"headline":"Memory corruption in EZ PLC Editor","id":"CVE-2019-13522"},"products":["Performance IP Cameras","Performance NVRs"],"published":"2019-09-26","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-04","vendors":["Honeywell"]},"summary":"Remote attackers can access sensitive web configuration data without authentication on Honeywell Performance IP Cameras and NVRs.","url":"https://insights.sbomify.com/CVE-2019-13523/"}