{"answers":{"affected":"It affects 2 products.","exploited":"There is no known exploitation of CVE-2019-13528 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2019-13528 yet. Limit exposure of the affected software until one is available.","what":"CVE-2019-13528 is a medium-severity missing authorization vulnerability in Niagara, published on 24 Sep 2019. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2019-13528 and fix it if it is affected.\n\nWhat it is: CVE-2019-13528 is a medium-severity missing authorization vulnerability in Niagara, published on 24 Sep 2019. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2019-13528 in the wild and no public exploit code.\n\nAffected product: Niagara. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2019-13528/ (Markdown: https://insights.sbomify.com/CVE-2019-13528/index.md)","id":"CVE-2019-13528","markdown":"https://insights.sbomify.com/CVE-2019-13528/index.md","name":"CVE-2019-13528","record":{"aliases":["GHSA-g38f-pqr8-74j5"],"analysis":{"component_type":"ics_ot","fix_type":"patch","impacts":["data_read"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Niagara building automation","requires_auth":"high_privilege","summary":"Attackers can read privileged files via a specific utility in Niagara building automation systems, exposing sensitive configuration data.","user_interaction":"not_required","vuln_class":"missing_authorization"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[{"product":"niagara4","vendor":"tridium"},{"product":"niagara_ax","vendor":"tridium"}],"cvss":{"score":4.4,"severity":"medium","source":"nvd","vector":"CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N","version":"3.1"},"cwes":[{"id":"CWE-285","name":"Improper Authorization"}],"description":"A specific utility may allow an attacker to gain read access to privileged files in the Niagara AX 3.8u4 (JACE 3e, JACE 6e, JACE 7, JACE-8000), Niagara 4.4u3 (JACE 3e, JACE 6e, JACE 7, JACE-8000), and Niagara 4.7u1 (JACE-8000, Edge 10).","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Missing authorization in Niagara","id":"CVE-2019-13528","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"missing_authorization","year":"2019"},"n_packages":0,"n_references":1,"next":{"headline":"Cross-site request forgery in Sunny WebBox","id":"CVE-2019-13529"},"packages":[],"prev":{"headline":"Null dereference in Rockwell Automation Arena Simulation Software Cat. 9502-Ax, Versions 16.00.00 and earlier","id":"CVE-2019-13527"},"products":["Niagara"],"published":"2019-09-24","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-04","vendors":["n/a"]},"summary":"Attackers can read privileged files via a specific utility in Niagara building automation systems, exposing sensitive configuration data.","url":"https://insights.sbomify.com/CVE-2019-13528/"}