{"answers":{"affected":"It affects 4 products.","exploited":"There is no known exploitation of CVE-2019-13534 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2019-13534 yet. Limit exposure of the affected software until one is available.","what":"CVE-2019-13534 is a high-severity vulnerability in Philips IntelliVue WLAN, portable patient monitors, published on 12 Sep 2019. An attacker needs administrator access to exploit it, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2019-13534 and fix it if it is affected.\n\nWhat it is: CVE-2019-13534 is a high-severity vulnerability in Philips IntelliVue WLAN, portable patient monitors, published on 12 Sep 2019. An attacker needs administrator access to exploit it, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2019-13534 in the wild and no public exploit code.\n\nAffected product: Philips IntelliVue WLAN, portable patient monitors. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2019-13534/ (Markdown: https://insights.sbomify.com/CVE-2019-13534/index.md)","id":"CVE-2019-13534","markdown":"https://insights.sbomify.com/CVE-2019-13534/index.md","name":"CVE-2019-13534","record":{"aliases":["GHSA-qc9c-3cxh-j47w"],"analysis":{"component_type":"iot_embedded","fix_type":"patch","impacts":["code_execution"],"network_reachable":"yes","non_default_config":false,"product_category":"Philips patient monitor","requires_auth":"high_privilege","summary":"Attackers can execute arbitrary code on Philips IntelliVue patient monitors by exploiting insufficient verification of downloaded code integrity.","user_interaction":"not_required","vuln_class":"supply_chain"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[{"product":"intellivue_mp_monitors_mp20-mp90_firmware","vendor":"philips"},{"product":"intellivue_mp_monitors_mp2\\/x2_firmware","vendor":"philips"},{"product":"intellivue_mp_monitors_mp5\\/5sc_firmware","vendor":"philips"},{"product":"intellivue_mp_monitors_mx800\\/700\\/600_firmware","vendor":"philips"}],"cvss":{"score":7.2,"severity":"high","source":"nvd","vector":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"cwes":[{"id":"CWE-494","name":"Download of Code Without Integrity Check"}],"description":"Philips IntelliVue WLAN, portable patient monitors, WLAN Version A, Firmware A.03.09, WLAN Version A, Firmware A.03.09, Part #: M8096-67501, WLAN Version B, Firmware A.01.09, Part #: N/A (Replaced by Version C) and WLAN Version B, Firmware A.01.09, Part #: N/A (Replaced by Version C). The product downloads source code or an executable from a remote location and executes the code without sufficiently verifying the origin and integrity of the code.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Supply chain in Philips IntelliVue WLAN, portable patient monitors","id":"CVE-2019-13534","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"supply_chain","year":"2019"},"n_packages":0,"n_references":1,"next":{"headline":"Medtronic Valleylab FT10 and LS10 Protection Mechanism Failure","id":"CVE-2019-13535"},"packages":[],"prev":{"headline":"Other in Omron PLC CJ and CS Series","id":"CVE-2019-13533"},"products":["Philips IntelliVue WLAN, portable patient monitors"],"published":"2019-09-12","related":[{"cvss_score":7.2,"headline":"Hardcoded credentials in Philips IntelliVue WLAN, portable patient monitors","id":"CVE-2019-13530","kev_date_added":null,"published":"2019-09-12"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-04","vendors":["n/a"]},"summary":"Attackers can execute arbitrary code on Philips IntelliVue patient monitors by exploiting insufficient verification of downloaded code integrity.","url":"https://insights.sbomify.com/CVE-2019-13534/"}