{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2019-13537 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2019-13537 yet. Limit exposure of the affected software until one is available.","what":"CVE-2019-13537 is a high-severity memory corruption vulnerability in AVEVA Vijeo Citect and Citect SCADA, published on 14 Jan 2020. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2019-13537 and fix it if it is affected.\n\nWhat it is: CVE-2019-13537 is a high-severity memory corruption vulnerability in AVEVA Vijeo Citect and Citect SCADA, published on 14 Jan 2020. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2019-13537 in the wild and no public exploit code.\n\nAffected product: AVEVA Vijeo Citect and Citect SCADA. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2019-13537/ (Markdown: https://insights.sbomify.com/CVE-2019-13537/index.md)","id":"CVE-2019-13537","markdown":"https://insights.sbomify.com/CVE-2019-13537/index.md","name":"CVE-2019-13537","record":{"aliases":["GHSA-hpw3-432w-cv6v"],"analysis":{"component_type":"ics_ot","fix_type":"patch","impacts":["denial_of_service"],"network_reachable":"yes","non_default_config":false,"product_category":"SCADA software","requires_auth":"none","summary":"A buffer overflow in the IEC870IP driver allows attackers to crash the SCADA server, impacting availability for industrial control systems.","user_interaction":"not_required","vuln_class":"memory_corruption"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[{"product":"iec870ip_firmware","vendor":"aveva"}],"cvss":{"score":7.5,"severity":"high","source":"nvd","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","version":"3.1"},"cwes":[{"id":"CWE-787","name":"Out-of-bounds Write"},{"id":"CWE-121","name":"Stack-based Buffer Overflow"}],"description":"The IEC870IP driver for AVEVA’s Vijeo Citect and Citect SCADA and Schneider Electric’s Power SCADA Operation has a buffer overflow vulnerability that could result in a server-side crash.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Memory corruption in Vijeo Citect and Citect SCADA","id":"CVE-2019-13537","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"memory_corruption","year":"2019"},"n_packages":0,"n_references":2,"next":{"headline":"Code injection in n/a","id":"CVE-2019-13538"},"packages":[],"prev":{"headline":"Memory corruption in TPEditor","id":"CVE-2019-13536"},"products":["Vijeo Citect and Citect SCADA"],"published":"2020-01-14","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-04","vendors":["AVEVA"]},"summary":"A buffer overflow in the IEC870IP driver allows attackers to crash the SCADA server, impacting availability for industrial control systems.","url":"https://insights.sbomify.com/CVE-2019-13537/"}