{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2019-13553 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2019-13553 yet. Limit exposure of the affected software until one is available.","what":"CVE-2019-13553 is a critical vulnerability in Rittal Chiller SK 3232-Series, published on 25 Oct 2019. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2019-13553 and fix it if it is affected.\n\nWhat it is: CVE-2019-13553 is a critical vulnerability in Rittal Chiller SK 3232-Series, published on 25 Oct 2019. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2019-13553 in the wild and no public exploit code.\n\nAffected product: Rittal Chiller SK 3232-Series. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2019-13553/ (Markdown: https://insights.sbomify.com/CVE-2019-13553/index.md)","id":"CVE-2019-13553","markdown":"https://insights.sbomify.com/CVE-2019-13553/index.md","name":"CVE-2019-13553","record":{"aliases":["GHSA-6j53-rvq8-q9pr"],"analysis":{"component_type":"ics_ot","fix_type":"patch","impacts":["privilege_escalation","data_modify"],"network_reachable":"yes","non_default_config":false,"product_category":"Industrial Chiller","requires_auth":"none","summary":"Hard-coded credentials in the Rittal Chiller web interface allow attackers to control cooling operations and modify temperature settings.","user_interaction":"not_required","vuln_class":"hardcoded_credentials"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[{"product":"pcoweb_firmware","vendor":"carel"}],"cvss":{"score":9.8,"severity":"critical","source":"nvd","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"cwes":[{"id":"CWE-798","name":"Use of Hard-coded Credentials"}],"description":"Rittal Chiller SK 3232-Series web interface as built upon Carel pCOWeb firmware A1.5.3 – B1.2.4. The authentication mechanism on affected systems is configured using hard-coded credentials. These credentials could allow attackers to influence the primary operations of the affected systems, namely turning the cooling unit on and off and setting the temperature set point.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Hardcoded credentials in Rittal Chiller SK 3232-Series","id":"CVE-2019-13553","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"hardcoded_credentials","year":"2019"},"n_packages":0,"n_references":2,"next":{"headline":"Hardcoded credentials in GE Mark VIe Controller","id":"CVE-2019-13554"},"packages":[],"prev":{"headline":"Command injection in WebAccess","id":"CVE-2019-13552"},"products":["Rittal Chiller SK 3232-Series"],"published":"2019-10-25","related":[{"cvss_score":7.5,"headline":"Missing authorization in Rittal Chiller SK 3232-Series","id":"CVE-2019-13549","kev_date_added":null,"published":"2019-10-25"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-04","vendors":["n/a"]},"summary":"Hard-coded credentials in the Rittal Chiller web interface allow attackers to control cooling operations and modify temperature settings.","url":"https://insights.sbomify.com/CVE-2019-13553/"}