{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2019-13923 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2019-13923 yet. Limit exposure of the affected software until one is available.","what":"CVE-2019-13923 is a critical cross-site scripting vulnerability in Siemens AG IE/WSN-PA Link WirelessHART Gateway, published on 13 Sep 2019. An attacker can exploit it over the internet without logging in, and only if a user opens a file or follows a link."},"fix_prompt":"Check this codebase for CVE-2019-13923 and fix it if it is affected.\n\nWhat it is: CVE-2019-13923 is a critical cross-site scripting vulnerability in Siemens AG IE/WSN-PA Link WirelessHART Gateway, published on 13 Sep 2019. An attacker can exploit it over the internet without logging in, and only if a user opens a file or follows a link.\nExploitation: There is no known exploitation of CVE-2019-13923 in the wild and no public exploit code.\n\nAffected product: Siemens AG IE/WSN-PA Link WirelessHART Gateway. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2019-13923/ (Markdown: https://insights.sbomify.com/CVE-2019-13923/index.md)","id":"CVE-2019-13923","markdown":"https://insights.sbomify.com/CVE-2019-13923/index.md","name":"CVE-2019-13923","record":{"aliases":["GHSA-726v-99qh-j9mj"],"analysis":{"component_type":"network_device","fix_type":"no_fix_stated","impacts":["security_bypass"],"network_reachable":"yes","non_default_config":false,"product_category":"WirelessHART Gateway","requires_auth":"none","summary":"Cross-Site Scripting in Siemens WirelessHART Gateway web server allows attackers to execute scripts if logged-in users visit malicious links.","user_interaction":"required","vuln_class":"xss"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"siemens","cpe":[{"product":"ie\\/wsn-pa_link_wirelesshart_gateway_firmware","vendor":"siemens"}],"cvss":{"score":9.6,"severity":"critical","source":"nvd","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:H","version":"3.1"},"cwes":[{"id":"CWE-79","name":"Improper Neutralization of Input During Web Page Generation"},{"id":"CWE-80","name":"Improper Neutralization of Script-Related HTML Tags in a Web Page"}],"description":"A vulnerability has been identified in IE/WSN-PA Link WirelessHART Gateway (All versions). The integrated configuration web server of the affected device could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into accessing a malicious link. User interaction is required for a successful exploitation. The user must be logged into the web interface in order for the exploitation to succeed. At the stage of publishing this security advisory no public exploitation is known.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Cross-site scripting in IE/WSN-PA Link WirelessHART Gateway","id":"CVE-2019-13923","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"xss","year":"2019"},"n_packages":0,"n_references":2,"next":{"headline":"Security feature bypass in SCALANCE S602","id":"CVE-2019-13924"},"packages":[],"prev":{"headline":"Information disclosure in SINEMA Remote Connect Server","id":"CVE-2019-13922"},"products":["IE/WSN-PA Link WirelessHART Gateway"],"published":"2019-09-13","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-05","vendors":["Siemens AG"]},"summary":"Cross-Site Scripting in Siemens WirelessHART Gateway web server allows attackers to execute scripts if logged-in users visit malicious links.","url":"https://insights.sbomify.com/CVE-2019-13923/"}